Benchtop Conductivity Meter LBCM-A14
Benchtop Conductivity Meter LBCM-A14
  • Conductivity Mode: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Conductivity measurement range</strong></td><td>0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>±1% F.S.</td></tr><tr><td><strong>Conductivity resolution</strong></td><td>0.001, 0.01, 0.1, 1</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 to 3 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm</td></tr></table>
  • TDS Mode: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>TDS measurement Range</strong></td><td>0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)</td></tr><tr><td><strong>TDS Accuracy</strong></td><td>± 1 % F.S.</td></tr><tr><td><strong>TDS Factor</strong></td><td>0.01 to 1.00 (default 0.5)</td></tr><tr><td><strong>TDS Calibration points</strong></td><td>3 points</td></tr></table>
  • Temperature Mode: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Temperature range</strong></td><td>0 to 105°C, 32 to 221°F</td></tr><tr><td><strong>Temperature accuracy</strong></td><td>±1°C</td></tr><tr><td><strong>Temperature resolution</strong></td><td>0.1°C, 0.1°F</td></tr><tr><td><strong>Temperature calibration points</strong></td><td>1 point</td></tr><tr><td><strong>Temperature Compensation Range and Mode</strong></td><td>Manual or Automatic, 0 to 100°C , 32 to 212°F</td></tr><tr><td><strong>Temperature coefficient</strong></td><td>0.0 to 10.0 % per °C</td></tr></table>
  • Cell constant: K=0.1, 1, 10
Portable Multi-parameter Water Quality Meter LMPWM-A10
Portable Multi-parameter Water Quality Meter LMPWM-A10
  • pH mode: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>pH measurement range</strong></td><td>(-2.000) to 20.000 pH</td></tr><tr><td><strong>pH accuracy</strong></td><td>± 0.002 pH</td></tr><tr><td><strong>pH calibration points</strong></td><td>1 - 5 points</td></tr><tr><td><strong>pH calibration solutions</strong></td><td>USA, NIST, DIN or user defined</td></tr></table>
  • ORP measurement: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>ORP measurement range</strong></td><td>-1999.9 to 1999.9 mV</td></tr><tr><td><strong>ORP accuracy</strong></td><td>±0.2 mV</td></tr><tr><td><strong>ORP calibration points</strong></td><td>1 point</td></tr><tr><td><strong>ORP calibration solutions</strong></td><td>mV & relative mV</td></tr></table>
  • Ion measurement: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Ion measurement range</strong></td><td>0 to 19999 ppm, mg/L, mol/L</td></tr><tr><td><strong>Ion accuracy</strong></td><td>± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)</td></tr><tr><td><strong>Ion calibration points</strong></td><td>2 - 5 points</td></tr><tr><td><strong>Ion calibration solutions</strong></td><td>0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L</td></tr></table>
  • Conductivity measurement: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Conductivity measurement range</strong></td><td>0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>± 0.5 % F.S.</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 - 5 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm</td></tr><tr><td><strong>Temperature coefficient</strong></td><td>0.0 to 10.0 % / °C</td></tr><tr><td><strong>Compensation modes</strong></td><td>Linear or pre water</td></tr><tr><td><strong>Cell constant</strong></td><td>K = 0.1, 1, 10 or user-defined</td></tr><tr><td><strong>Normalization temperature</strong></td><td>20 °C or 25 °C</td></tr></table>
Portable Multi-parameter Water Quality Meter LMPWM-A11
Portable Multi-parameter Water Quality Meter LMPWM-A11
  • pH mode: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>pH measurement range</strong></td><td>(-2.000) to 20.000 pH</td></tr><tr><td><strong>pH accuracy</strong></td><td>± 0.002 pH</td></tr><tr><td><strong>pH calibration points</strong></td><td>1 - 5 points</td></tr><tr><td><strong>pH calibration solutions</strong></td><td>USA, NIST, DIN or user defined</td></tr></table>
  • ORP measurement: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>ORP measurement range</strong></td><td>-1999.9 to 1999.9 mV</td></tr><tr><td><strong>ORP accuracy</strong></td><td>±0.2 mV</td></tr><tr><td><strong>ORP calibration points</strong></td><td>1 point</td></tr><tr><td><strong>ORP calibration solutions</strong></td><td>mV & relative mV</td></tr></table>
  • Ion measurement: <table class='table table-striped table-bordered table-responsive'></table>
  • Conductivity measurement: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Conductivity measurement range</strong></td><td>0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>± 0.5 % F.S.</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 - 5 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm</td></tr><tr><td><strong>Temperature coefficient</strong></td><td>0.0 to 10.0 % / °C</td></tr><tr><td><strong>Compensation modes</strong></td><td>Linear or pre water</td></tr><tr><td><strong>Cell constant</strong></td><td>K = 0.1, 1, 10 or user-defined</td></tr><tr><td><strong>Normalization temperature</strong></td><td>20 °C or 25 °C</td></tr></table>
Portable Multi-parameter Water Quality Meter LMPWM-A20
Portable Multi-parameter Water Quality Meter LMPWM-A20
  • pH mode: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>pH measurement range</strong></td><td>(-2.000) to 20.000 pH</td></tr><tr><td><strong>pH accuracy</strong></td><td>± 0.002 pH</td></tr><tr><td><strong>pH calibration points</strong></td><td>1 - 5 points</td></tr><tr><td><strong>pH calibration solutions</strong></td><td>USA, NIST, DIN or user defined</td></tr></table>
  • ORP measurement: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>ORP measurement range</strong></td><td>-1999.9 to 1999.9 mV</td></tr><tr><td><strong>ORP accuracy</strong></td><td>±0.2 mV</td></tr><tr><td><strong>ORP calibration points</strong></td><td>1 point</td></tr><tr><td><strong>ORP calibration solutions</strong></td><td>mV & relative mV</td></tr></table>
  • Conductivity measurement: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Conductivity measurement range</strong></td><td>0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>± 0.5 % F.S.</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 - 5 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm</td></tr><tr><td><strong>Temperature coefficient</strong></td><td>0.0 to 10.0 % / °C</td></tr><tr><td><strong>Compensation modes</strong></td><td>Linear or pre water</td></tr><tr><td><strong>Cell constant</strong></td><td>K = 0.1, 1, 10 or user-defined</td></tr><tr><td><strong>Normalization temperature</strong></td><td>20 °C or 25 °C</td></tr></table>
  • TDS measurement: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>TDS range</strong></td><td>0-100 ppt. (max. 200 ppt., depending on factor setting)</td></tr><tr><td><strong>TDS accuracy</strong></td><td>± 1 % F.S.</td></tr><tr><td><strong>TDS factor</strong></td><td>0.1 - 1.0 (default 0.5)</td></tr></table>
Portable Multi-parameter Water Quality Meter LMPWM-A21
Portable Multi-parameter Water Quality Meter LMPWM-A21
  • pH mode: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>pH measurement range</strong></td><td>(-2.000) to 20.000 pH</td></tr><tr><td><strong>pH accuracy</strong></td><td>± 0.002 pH</td></tr><tr><td><strong>pH calibration points</strong></td><td>1 - 5 points</td></tr><tr><td><strong>pH calibration solutions</strong></td><td>USA, NIST, DIN or user defined</td></tr></table>
  • ORP measurement: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>ORP measurement range</strong></td><td>-1999.9 to 1999.9 mV</td></tr><tr><td><strong>ORP accuracy</strong></td><td>±0.2 mV</td></tr><tr><td><strong>ORP calibration points</strong></td><td>1 point</td></tr><tr><td><strong>ORP calibration solutions</strong></td><td>mV & relative mV</td></tr></table>
  • Dissolved oxygen: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>DO concentration range</strong></td><td>0.00 to 20.00 mg/L</td></tr><tr><td><strong>DO accuracy</strong></td><td>± 0.2 mg/L</td></tr><tr><td><strong>Calibration points</strong></td><td>1 - 2 points</td></tr><tr><td><strong>Pressure correction</strong></td><td>60.0 to 112.5 kPa, 450 - 850 mmHg</td></tr><tr><td><strong>Salinity correction</strong></td><td>0 to 50 g/L</td></tr><tr><td><strong>% Saturation of Oxygen</strong></td><td>0.0 to 200.0 %</td></tr><tr><td><strong>Accuracy</strong></td><td>± 2.0 %</td></tr></table>
  • Temperature compensation: 0 to 100 °C, 32 to 212 °F, Manual or Automatic
Multi parameter water quality analyzer LMWA-A10
Multi parameter water quality analyzer LMWA-A10
  • COD: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>COD determination range</strong></td><td>2 to 10000 mg/ L</td></tr><tr><td><strong>COD measurement accuracy</strong></td><td>COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %</td></tr><tr><td><strong>COD minimum detection limit</strong></td><td>0.1 mg/ L</td></tr><tr><td><strong>COD measurement time</strong></td><td>20 minutes</td></tr><tr><td><strong>COD repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Consumables for colorimetric COD measurement</strong></td><td>Colorimetric tubes and Cuvette</td></tr><tr><td><strong>COD reactor digestion temperature</strong></td><td>165 ± 0.5°C</td></tr><tr><td><strong>COD reactor digestion time</strong></td><td>10 min</td></tr><tr><td><strong>COD reactor time setting switches</strong></td><td>3 pcs</td></tr><tr><td><strong>Anti-chlorine interference</strong></td><td>(Cl) < 1000 mg/ L No effect</td></tr></table>
  • Ammonia nitrogen: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Ammonia nitrogen determination range</strong></td><td>0.02 to 60 mg/ L</td></tr><tr><td><strong>Ammonia nitrogen measurement accuracy</strong></td><td>≤ ± 10 %</td></tr><tr><td><strong>Ammonia nitrogen minimum detection limit</strong></td><td>0.01 mg/ L</td></tr><tr><td><strong>Ammonia nitrogen measurement time</strong></td><td>10 to 15 minutes</td></tr><tr><td><strong>Ammonia nitrogen repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Consumables for colorimetric ammonia nitrogen measurement</strong></td><td>Colorimetric tubes and Cuvette</td></tr><tr><td><strong>Ammonia nitrogen reactor time setting switches</strong></td><td>3 pcs</td></tr></table>
  • Total phosphorous: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Total phosphorous determination range</strong></td><td>0.002 to 20 mg/ L</td></tr><tr><td><strong>Total phosphorous total phosphorous measurement accuracy</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Total phosphorous minimum detection limit</strong></td><td>0.001 mg/ L</td></tr><tr><td><strong>Total phosphorous measurement time</strong></td><td>35 to 50 minutes</td></tr><tr><td><strong>Total phosphorous repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Consumables for colorimetric total phosphorous measurement</strong></td><td>Colorimetric tubes and Cuvette</td></tr><tr><td><strong>Total phosphorous reactor digestion temperature</strong></td><td>120 ± 0.5°C</td></tr><tr><td><strong>Total phosphorous reactor digestion time</strong></td><td>30 min</td></tr><tr><td><strong>Total phosphorous reactor time setting switches</strong></td><td>3 pcs</td></tr></table>
  • Turbidity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Turbidity determination range</strong></td><td>0.5 to 400 NTU</td></tr><tr><td><strong>Turbidity measurement accuracy</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Turbidity minimum detection limit</strong></td><td>0.1 NTU</td></tr><tr><td><strong>Turbidity measurement time</strong></td><td>1 minute</td></tr><tr><td><strong>Turbidity repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Consumables for colorimetric turbidity measurement</strong></td><td>Colorimetric Cuvette</td></tr></table>
Multi parameter water quality analyzer LMWA-A11
Multi parameter water quality analyzer LMWA-A11
  • COD: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>COD determination range</strong></td><td>5 to 5000 mg/ L</td></tr><tr><td><strong>COD measurement accuracy</strong></td><td>COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %</td></tr><tr><td><strong>COD minimum detection limit</strong></td><td>0.1 mg/ L</td></tr><tr><td><strong>COD measurement time</strong></td><td>20 minutes</td></tr><tr><td><strong>COD repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Processing sample number per batch</strong></td><td>12 pcs</td></tr><tr><td><strong>Consumables for colorimetric COD measurement</strong></td><td>Colorimetric tubes and Cuvette</td></tr><tr><td><strong>COD reactor digestion temperature</strong></td><td>165 ± 0.5°C</td></tr><tr><td><strong>COD reactor digestion time</strong></td><td>10 min</td></tr><tr><td><strong>COD reactor time setting switches</strong></td><td>3 pcs</td></tr><tr><td><strong>Anti-chlorine interference</strong></td><td>(Cl) < 1000 mg/ L No effect</td></tr></table>
  • Ammonia nitrogen: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Ammonia nitrogen determination range</strong></td><td>0.02 to 30 mg/ L</td></tr><tr><td><strong>Ammonia nitrogen measurement accuracy</strong></td><td>≤ ± 10 %</td></tr><tr><td><strong>Ammonia nitrogen minimum detection limit</strong></td><td>0.01 mg/ L</td></tr><tr><td><strong>Ammonia nitrogen measurement time</strong></td><td>10 to 15 minutes</td></tr><tr><td><strong>Ammonia nitrogen repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Processing sample number per batch</strong></td><td>20 pcs</td></tr><tr><td><strong>Consumables for colorimetric ammonia nitrogen measurement</strong></td><td>Colorimetric tubes and Cuvette</td></tr><tr><td><strong>Ammonia nitrogen reactor time setting switches</strong></td><td>3 pcs</td></tr></table>
  • Total phosphorous: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Total phosphorous determination range</strong></td><td>0.002 to 10 mg/ L</td></tr><tr><td><strong>Total phosphorous total phosphorous measurement accuracy</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Total phosphorous minimum detection limit</strong></td><td>0.001 mg/ L</td></tr><tr><td><strong>Total phosphorous measurement time</strong></td><td>35 to 50 minutes</td></tr><tr><td><strong>Total phosphorous repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Processing sample number per batch</strong></td><td>12 pcs</td></tr><tr><td><strong>Consumables for colorimetric total phosphorous measurement</strong></td><td>Colorimetric tubes and Cuvette</td></tr><tr><td><strong>Total phosphorous reactor digestion temperature</strong></td><td>120 ± 0.5°C</td></tr><tr><td><strong>Total phosphorous reactor digestion time</strong></td><td>30 min</td></tr><tr><td><strong>Total phosphorous reactor time setting switches</strong></td><td>3 pcs</td></tr></table>
  • Turbidity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Turbidity determination range</strong></td><td>0.5 to 400 NTU</td></tr><tr><td><strong>Turbidity measurement accuracy</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Turbidity minimum detection limit</strong></td><td>0.1 NTU</td></tr><tr><td><strong>Turbidity measurement time</strong></td><td>1 minute</td></tr><tr><td><strong>Turbidity repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Consumables for colorimetric turbidity measurement</strong></td><td>Colorimetric Cuvette</td></tr></table>
Benchtop Multi-parameter Water Quality Meter LMPWM-A30
Benchtop Multi-parameter Water Quality Meter LMPWM-A30
  • pH Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>pH range </td> <td style=min-width:50px>-2.00 to 20.00 pH</td> </tr> <tr> <td style=min-width:50px>pH Accuracy </td> <td style=min-width:50px>± 0.002 pH</td> </tr> <tr> <td style=min-width:50px>pH Resolution </td> <td style=min-width:50px>0.1/0.01/0.001 pH, selectable</td> </tr> <tr> <td style=min-width:50px>pH Calibration Points </td> <td style=min-width:50px>1 to 5 Points</td> </tr> <tr> <td style=min-width:50px>pH Buffer Solutions </td> <td style=min-width:50px>USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers</td> </tr> </table>
  • mV Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>mV Range </td> <td style=min-width:50px>-1999.9 to 1999.9 mV</td> </tr> <tr> <td style=min-width:50px>mV Accuracy </td> <td style=min-width:50px>± 0.2 mV</td> </tr> <tr> <td style=min-width:50px>mV Resolution </td> <td style=min-width:50px>0.1/1 mV, selectable</td> </tr> <tr> <td style=min-width:50px>mV Calibration Points</td> <td style=min-width:50px>1 Point</td> </tr> </table>
  • Conductivity Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Conductivity Range </td> <td style=min-width:50px>0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm</td> </tr> <tr> <td style=min-width:50px>Conductivity Accuracy </td> <td style=min-width:50px>± 0.5% F.S.</td> </tr> <tr> <td style=min-width:50px>Conductivity Resolution</td> <td style=min-width:50px>0.01/0.1/1</td> </tr> <tr> <td style=min-width:50px>Conductivity Calibration Points</td> <td style=min-width:50px>1 to 5 Points</td> </tr> <tr> <td style=min-width:50px>Conductivity Solutions</td> <td style=min-width:50px>10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm</td> </tr> <tr> <td style=min-width:50px>Conductivity Temperature coefficient </td> <td style=min-width:50px>0.0 to 10.0 %/°C</td> </tr> <tr> <td style=min-width:50px>Compensation mode </td> <td style=min-width:50px>Linear or Pure Water</td> </tr> <tr> <td style=min-width:50px>Cell Constant</td> <td style=min-width:50px>K=0.1, 1, 10 or Custom</td> </tr> <tr> <td style=min-width:50px>Reference temperature </td> <td style=min-width:50px>20 or 25°C</td> </tr> </table>
  • TDS Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>TDS Range</td> <td style=min-width:50px>0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)</td> </tr> <tr> <td style=min-width:50px>TDS Accuracy </td> <td style=min-width:50px>± 1 % F.S.</td> </tr> <tr> <td style=min-width:50px>TDS Factor </td> <td style=min-width:50px>0.1  to 1.0 (default 0.5)</td> </tr> </table>
Benchtop Multi-parameter Water Quality Meter LMPWM-A31
Benchtop Multi-parameter Water Quality Meter LMPWM-A31
  • pH Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>pH range </td> <td style=min-width:50px>-2.00 to 20.00 pH</td> </tr> <tr> <td style=min-width:50px>pH Accuracy </td> <td style=min-width:50px>± 0.002 pH</td> </tr> <tr> <td style=min-width:50px>pH Resolution </td> <td style=min-width:50px>0.1/0.01/0.001 pH, selectable</td> </tr> <tr> <td style=min-width:50px>pH Calibration Points </td> <td style=min-width:50px>1 to 5 Points</td> </tr> <tr> <td style=min-width:50px>pH Buffer Solutions </td> <td style=min-width:50px>USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers</td> </tr> </table>
  • mV Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>mV Range </td> <td style=min-width:50px>-1999.9 to 1999.9 mV</td> </tr> <tr> <td style=min-width:50px>mV Accuracy </td> <td style=min-width:50px>± 0.2 mV</td> </tr> <tr> <td style=min-width:50px>mV Resolution </td> <td style=min-width:50px>0.1/1 mV, selectable</td> </tr> <tr> <td style=min-width:50px>mV Calibration Points</td> <td style=min-width:50px>1 Point</td> </tr> </table>
  • Conductivity Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Conductivity Range </td> <td style=min-width:50px>0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm</td> </tr> <tr> <td style=min-width:50px>Conductivity Accuracy </td> <td style=min-width:50px>± 0.5% F.S.</td> </tr> <tr> <td style=min-width:50px>Conductivity Resolution</td> <td style=min-width:50px>0.01/0.1/1</td> </tr> <tr> <td style=min-width:50px>Conductivity Calibration Points</td> <td style=min-width:50px>1 to 5 Points</td> </tr> <tr> <td style=min-width:50px>Conductivity Solutions</td> <td style=min-width:50px>10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm</td> </tr> <tr> <td style=min-width:50px>Conductivity Temperature coefficient </td> <td style=min-width:50px>0.0 to 10.0 %/°C</td> </tr> <tr> <td style=min-width:50px>Compensation mode </td> <td style=min-width:50px>Linear or Pure Water</td> </tr> <tr> <td style=min-width:50px>Cell Constant</td> <td style=min-width:50px>K=0.1, 1, 10 or Custom</td> </tr> <tr> <td style=min-width:50px>Reference temperature </td> <td style=min-width:50px>20 or 25°C</td> </tr> </table>
  • TDS Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>TDS Range</td> <td style=min-width:50px>0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)</td> </tr> <tr> <td style=min-width:50px>TDS Accuracy </td> <td style=min-width:50px>± 1 % F.S.</td> </tr> <tr> <td style=min-width:50px>TDS Factor </td> <td style=min-width:50px>0.1  to 1.0 (default 0.5)</td> </tr> </table>
Benchtop Multi-parameter Water Quality Meter LMPWM-A32
Benchtop Multi-parameter Water Quality Meter LMPWM-A32
  • pH Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>pH range </td> <td style=min-width:50px>-2.00 to 20.00 pH</td> </tr> <tr> <td style=min-width:50px>pH Accuracy </td> <td style=min-width:50px>± 0.002 pH</td> </tr> <tr> <td style=min-width:50px>pH Resolution </td> <td style=min-width:50px>0.1/0.01/0.001 pH, selectable</td> </tr> <tr> <td style=min-width:50px>pH Calibration Points </td> <td style=min-width:50px>1 to 5 Points</td> </tr> <tr> <td style=min-width:50px>pH Buffer Solutions </td> <td style=min-width:50px>USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers</td> </tr> </table>
  • mV Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>mV Range </td> <td style=min-width:50px>-1999.9 to 1999.9 mV</td> </tr> <tr> <td style=min-width:50px>mV Accuracy </td> <td style=min-width:50px>± 0.2 mV</td> </tr> <tr> <td style=min-width:50px>mV Resolution </td> <td style=min-width:50px>0.1/1 mV, selectable</td> </tr> <tr> <td style=min-width:50px>mV Calibration Points</td> <td style=min-width:50px>1 Point</td> </tr> </table>
  • Conductivity Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Conductivity Range </td> <td style=min-width:50px>0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm</td> </tr> <tr> <td style=min-width:50px>Conductivity Accuracy </td> <td style=min-width:50px>± 0.5% F.S.</td> </tr> <tr> <td style=min-width:50px>Conductivity Resolution</td> <td style=min-width:50px>0.01/0.1/1</td> </tr> <tr> <td style=min-width:50px>Conductivity Calibration Points</td> <td style=min-width:50px>1 to 5 Points</td> </tr> <tr> <td style=min-width:50px>Conductivity Solutions</td> <td style=min-width:50px>10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm</td> </tr> <tr> <td style=min-width:50px>Conductivity Temperature coefficient </td> <td style=min-width:50px>0.0 to 10.0 %/°C</td> </tr> <tr> <td style=min-width:50px>Compensation mode </td> <td style=min-width:50px>Linear or Pure Water</td> </tr> <tr> <td style=min-width:50px>Cell Constant</td> <td style=min-width:50px>K=0.1, 1, 10 or Custom</td> </tr> <tr> <td style=min-width:50px>Reference temperature </td> <td style=min-width:50px>20 or 25°C</td> </tr> </table>
  • Dissolved Oxygen Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Dissolved Oxygen Range </td> <td style=min-width:50px>0.00 to 20.00 mg/ L</td> </tr> <tr> <td style=min-width:50px>Dissolved Oxygen Accuracy </td> <td style=min-width:50px>± 0.2 mg/ L</td> </tr> <tr> <td style=min-width:50px>Dissolved Oxygen Resolution</td> <td style=min-width:50px>0.1/ 0.01 mg/ L, selectable</td> </tr> <tr> <td style=min-width:50px>Dissolved Oxygen Calibration Points</td> <td style=min-width:50px>1 or 2 Points</td> </tr> <tr> <td style=min-width:50px>% Saturation Range</td> <td style=min-width:50px>0.0 to 200.0 % with ± 2 % accuracy</td> </tr> <tr> <td style=min-width:50px>Pressure correction </td> <td style=min-width:50px>60 to 112.5 kPa, 450 to 850 mmHg</td> </tr> <tr> <td style=min-width:50px>Salinity correction </td> <td style=min-width:50px>0 to 50 g/ L</td> </tr> </table>
Benchtop Multi-parameter Water Quality Meter LMPWM-A40
Benchtop Multi-parameter Water Quality Meter LMPWM-A40
  • pH Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>pH range </td> <td style=min-width:50px>-2.00 to 20.00 pH</td> </tr> <tr> <td style=min-width:50px>pH Accuracy </td> <td style=min-width:50px>± 0.002 pH</td> </tr> <tr> <td style=min-width:50px>pH Resolution </td> <td style=min-width:50px>0.1/0.01/0.001 pH, selectable</td> </tr> <tr> <td style=min-width:50px>pH Calibration Points </td> <td style=min-width:50px>1 to 5 Points</td> </tr> <tr> <td style=min-width:50px>pH Buffer Solutions </td> <td style=min-width:50px>USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers</td> </tr> </table>
  • ORP Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>mV Range </td> <td style=min-width:50px>± 2000 mV</td> </tr> <tr> <td style=min-width:50px>mV Accuracy </td> <td style=min-width:50px>± 0.2 mV</td> </tr> <tr> <td style=min-width:50px>mV Resolution </td> <td style=min-width:50px>0.1 mV, selectable</td> </tr> <tr> <td style=min-width:50px>mV Calibration Points</td> <td style=min-width:50px>1 Point, only for relative mode</td> </tr> </table>
  • Ion Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Ion measurement range </td> <td style=min-width:50px>0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range of ion selection) </td> </tr> <tr> <td style=min-width:50px>Ion measurement accuracy</td> <td style=min-width:50px>±0.5% F.S (Monovalent), ±1% F.S (Divalent)</td> </tr> <tr> <td style=min-width:50px>Ion measurement resolution</td> <td style=min-width:50px>0.001/0.01/0.1/1</td> </tr> <tr> <td style=min-width:50px>Ion measurement calibration points</td> <td style=min-width:50px>2 to 5 points</td> </tr> <tr> <td style=min-width:50px>Ion measurement calibration solutions</td> <td style=min-width:50px>0.001/0.01/0.1/1/10/100/1000/10000 ppm, mg/L, mol/L</td> </tr> <tr> <td style=min-width:50px>Ion measurement methods</td> <td style=min-width:50px>Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction</td> </tr> </table>
  • Water Hardness Mode: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Water hardness measurement range </td> <td style=min-width:50px>0.05-200mmol/L, 0-1120°dH, 0-1404°e, 0-2000°fH, 0-8000mg/L (Ca2+), 0~19999mg/L (CaCO3)</td> </tr> <tr> <td style=min-width:50px>Water hardness measurement accuracy</td> <td style=min-width:50px>±1% F.S</td> </tr> <tr> <td style=min-width:50px>Water hardness measurement resolution</td> <td style=min-width:50px>0.001/0.01/0.1/1</td> </tr> <tr> <td style=min-width:50px>Water hardness calibration points</td> <td style=min-width:50px>2 to 5 points</td> </tr> <tr> <td style=min-width:50px>Water hardness calibration solutions</td> <td style=min-width:50px>0.01/0.1/1/10/100 mmol/L</td> </tr> </table>
Portable Conductivity Meter LPCM-A11
Portable Conductivity Meter LPCM-A11
  • Conductivity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Conductivity measurement range</strong></td><td>0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>±0.5% F.S</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 to 5 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom</td></tr><tr><td><strong>Conductivity resolution</strong></td><td>0.001, 0.01, 0.1, 1</td></tr></table>
  • TDS: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>TDS range</strong></td><td>0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)</td></tr><tr><td><strong>TDS accuracy</strong></td><td>±1 % F.S</td></tr><tr><td><strong>TDS factor</strong></td><td>0.01 to 1.00 (Default 0.5)</td></tr><tr><td><strong>TDS resolution</strong></td><td>0.01, 0.1, 1</td></tr></table>
  • Temperature: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Temperature measuring range</strong></td><td>0 105 °C, 32 to 221 °F</td></tr><tr><td><strong>Temperature measuring accuracy</strong></td><td>± °0.5 C, ± 0.9 °F</td></tr><tr><td><strong>Temperature calibration points</strong></td><td>1 point</td></tr><tr><td><strong>Temperature resolution</strong></td><td>0.1 °C, 0.1 °F</td></tr></table>
  • Temperature compensation: 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Portable Conductivity Meter LPCM-A12
Portable Conductivity Meter LPCM-A12
  • Conductivity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Conductivity measurement range</strong></td><td>0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>±0.5% F.S</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 to 5 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom</td></tr><tr><td><strong>Conductivity resolution</strong></td><td>0.001, 0.01, 0.1, 1</td></tr></table>
  • Salinity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Salinity range</strong></td><td>0.00 to 80.00 ppt, 0.00 to 42.00 psu</td></tr><tr><td><strong>Salinity accuracy</strong></td><td>±1% F.S</td></tr><tr><td><strong>Salinity measurement modes</strong></td><td>Practical Salinity (psu) or Natural Seawater (ppt)</td></tr><tr><td><strong>Salinity resolution</strong></td><td>0.01, 0.1, 1</td></tr></table>
  • Temperature: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Temperature measuring range</strong></td><td>0 105 °C, 32 to 221 °F</td></tr><tr><td><strong>Temperature measuring accuracy</strong></td><td>± °0.5 C, ± 0.9 °F</td></tr><tr><td><strong>Temperature calibration points</strong></td><td>1 point</td></tr><tr><td><strong>Temperature resolution</strong></td><td>0.1 °C, 0.1 °F</td></tr></table>
  • Temperature compensation: 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Portable Conductivity Meter LPCM-A13
Portable Conductivity Meter LPCM-A13
  • Conductivity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Conductivity measurement range</strong></td><td>0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>±0.5% F.S</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 to 5 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom</td></tr><tr><td><strong>Conductivity resolution</strong></td><td>0.001, 0.01, 0.1, 1</td></tr></table>
  • TDS: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>TDS range</strong></td><td>0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)</td></tr><tr><td><strong>TDS accuracy</strong></td><td>±1 % F.S</td></tr><tr><td><strong>TDS factor</strong></td><td>0.01 to 1.00 (Default 0.5)</td></tr><tr><td><strong>TDS resolution</strong></td><td>0.01, 0.1, 1</td></tr></table>
  • Salinity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Salinity range</strong></td><td>0.00 to 80.00 ppt, 0.00 to 42.00 psu</td></tr><tr><td><strong>Salinity accuracy</strong></td><td>±1% F.S</td></tr><tr><td><strong>Salinity measurement modes</strong></td><td>Practical Salinity (psu) or Natural Seawater (ppt)</td></tr><tr><td><strong>Salinity resolution</strong></td><td>0.01, 0.1, 1</td></tr></table>
  • Resistivity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Resistivity range</strong></td><td>0.00 to 20 MΩ</td></tr><tr><td><strong>Resistivity accuracy</strong></td><td>±1% F.S</td></tr><tr><td><strong>Resistivity resolution</strong></td><td>0.01, 0.1, 1</td></tr></table>