Portable Conductivity Meter LPCM-A10 is adapted for measuring quality of water on parameter such as conductivity and TDS. Due to its portable design, it is suitable for outdoor measurements i.e. on site water testing, remote area water testing and for research purpose. It is reliable and user friendly.

Conductivity <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Conductivity measurement range</strong></td><td>0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>±0.5% F.S</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 to 3 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom</td></tr><tr><td><strong>Conductivity resolution</strong></td><td>0.001, 0.01, 0.1, 1</td></tr></table>
Temperature <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Temperature measuring range</strong></td><td>0 105 °C, 32 to 221 °F</td></tr><tr><td><strong>Temperature measuring accuracy</strong></td><td>± °0.5 C, ± 0.9 °F</td></tr><tr><td><strong>Temperature calibration points</strong></td><td>1 point</td></tr><tr><td><strong>Temperature resolution</strong></td><td>0.1 °C, 0.1 °F</td></tr></table>
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient Linear
Reference temperature 25 °C
Stability conditions Low or high
Cell constant K= 0.1, 1, 10 or custom
Calibration due 1 to 31 days or off
Memory 100 data sets
Data hold Manual or auto-end point
Connector 6 pin mini plug
Power Control Manual or Automatic (10, 20 or 30 minutes after last key pressed)
Power 3 × 1.5 V AA batteries or DC 5 V power adapter
Dimension (L × W × H) 170 × 85 × 30 mm
Weight 300 g
  • Common features
  • Calibration due reminder informs operator to calibrate the meter regularly
  • Stability indicator displays the status of current measurement
  • Auto hold function freezes stable, final readings for better viewing and recording
  • 1 to 3 points push button calibration to automatically identify calibration solutions
  • Selectable temperature units (°C or °F) for different application requirements
  • Expanded memory stores and recalls up to 500 readings
  • Calibration report provides details of calibration standard and cell constant
  • Help message as an operational guide, helps users for quick access to the parameters
  • Reset function automatically resumes all settings back to factory default options
  • Store data is transferrable into computer via USB communication interface
  • Conductivity / Temperature
  • Conductivity: 1 to 3 point calibration with automatically identification of calibration solutions
  • Temperature: Can select cell constant (0.1/1/10) and normalization temperature 25°C
  • Linear compensation improves the measurement accuracy
Used for quality testing of water on different parameters in research and development labs, water resources and plants in nearby or remote area.

Portable Conductivity Meter

Portable Conductivity Meter LPCM-A12

Portable Conductivity Meter LPCM-A12

  • Conductivity
  • Conductivity measurement range0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cmConductivity accuracy±0.5% F.SConductivity calibration points1 to 5 pointsConductivity calibration solutions10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or CustomConductivity resolution0.001, 0.01, 0.1, 1
  • Salinity
  • Salinity range0.00 to 80.00 ppt, 0.00 to 42.00 psuSalinity accuracy±1% F.SSalinity measurement modesPractical Salinity (psu) or Natural Seawater (ppt)Salinity resolution0.01, 0.1, 1
  • Temperature
  • Temperature measuring range0 105 °C, 32 to 221 °FTemperature measuring accuracy± °0.5 C, ± 0.9 °FTemperature calibration points1 pointTemperature resolution0.1 °C, 0.1 °F
Portable Conductivity Meter LPCM-A11

Portable Conductivity Meter LPCM-A11

  • Conductivity
  • Conductivity measurement range0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cmConductivity accuracy±0.5% F.SConductivity calibration points1 to 5 pointsConductivity calibration solutions10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or CustomConductivity resolution0.001, 0.01, 0.1, 1
  • TDS
  • TDS range0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS accuracy±1 % F.STDS factor0.01 to 1.00 (Default 0.5)TDS resolution0.01, 0.1, 1
  • Temperature
  • Temperature measuring range0 105 °C, 32 to 221 °FTemperature measuring accuracy± °0.5 C, ± 0.9 °FTemperature calibration points1 pointTemperature resolution0.1 °C, 0.1 °F
Portable Conductivity Meter LPCM-A13

Portable Conductivity Meter LPCM-A13

  • Conductivity
  • Conductivity measurement range0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cmConductivity accuracy±0.5% F.SConductivity calibration points1 to 5 pointsConductivity calibration solutions10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or CustomConductivity resolution0.001, 0.01, 0.1, 1
  • TDS
  • TDS range0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS accuracy±1 % F.STDS factor0.01 to 1.00 (Default 0.5)TDS resolution0.01, 0.1, 1
  • Salinity
  • Salinity range0.00 to 80.00 ppt, 0.00 to 42.00 psuSalinity accuracy±1% F.SSalinity measurement modesPractical Salinity (psu) or Natural Seawater (ppt)Salinity resolution0.01, 0.1, 1

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop pH meter LBPM-A11

Benchtop pH meter LBPM-A11

  • pH measurement range
  • 0.00 to 14.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH
Benchtop pH meter LBPM-B10

Benchtop pH meter LBPM-B10

  • pH measurement range
  • -2.000 to 20.000 pH
  • pH accuracy
  • ± 0.002 pH
  • Calibration points
  • 1-5 points
Benchtop pH meter LBPM-A20

Benchtop pH meter LBPM-A20

  • pH measurement range
  • -1.00 to 15.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH
Benchtop pH Meter LBPM-B11

Benchtop pH Meter LBPM-B11

  • Temperature compensation
  • 0 to 100°C, 32°F to 212°F Manual or Automatic
  • Hold function
  • Manual or automatic endpoint detection
  • Stability criteria
  • Standard or High-accuracy

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Conductivity Meter LBCM-A13

Benchtop Conductivity Meter LBCM-A13

  • Conductivity measurement range
  • 0.000 μS/cm to 3000mS/cm
  • Resistivity measurement range
  • 5.00 Ω·cm to 100.0 MΩ·cm
  • TDS measurement range
  • 0.000 mg/L to 1000g/L
Benchtop Conductivity Meter LBCM-A14

Benchtop Conductivity Meter LBCM-A14

  • Conductivity Mode
  • Conductivity measurement range0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cmConductivity accuracy±1% F.S.Conductivity resolution0.001, 0.01, 0.1, 1Conductivity calibration points1 to 3 pointsConductivity calibration solutions10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
  • TDS Mode
  • TDS measurement Range0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS Accuracy± 1 % F.S.TDS Factor0.01 to 1.00 (default 0.5)TDS Calibration points3 points
  • Temperature Mode
  • Temperature range0 to 105°C, 32 to 221°FTemperature accuracy±1°CTemperature resolution0.1°C, 0.1°FTemperature calibration points1 pointTemperature Compensation Range and ModeManual or Automatic, 0 to 100°C , 32 to 212°FTemperature coefficient0.0 to 10.0 % per °C
Benchtop conductivity meter LBCM-A11

Benchtop conductivity meter LBCM-A11

  • Conductivity measurement range
  • 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy
  • ± 1 % F.S.
  • Conductivity resolution
  • 0.01, 0.1, 1

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A10

Benchtop Dissolved oxygen meter LBDO-A10

  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.5 mg / L
  • Resolution
  • 0.1 mg / L
Benchtop Dissolved oxygen meter LBDO-A11

Benchtop Dissolved oxygen meter LBDO-A11

  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.2 mg / L
  • Resolution
  • 0.01 mg / L

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for Cl, LBIM-A10

Benchtop Ion meter for Cl, LBIM-A10

  • Ion measurement range
  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion  meter  for K, LBIM-A23

Benchtop Ion meter for K, LBIM-A23

  • Ion measurement range
  • K range: 1×106 - 1M, 0.04 -39000 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion meter for Cn, LBIM-A21

Benchtop Ion meter for Cn, LBIM-A21

  • Ion measurement range
  • Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion meter for Cu, LBIM-A27

Benchtop Ion meter for Cu, LBIM-A27

  • Ion measurement range
  • Cu range: 1×108 - 1M, 0.06-6400 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1