Benchtop Conductivity Meter LBCM-A13 with 7 inch display conducts up to 5 point calibration, automatically recognizes calibration standards. Comes with 03 reading mode: fast, medium, strict, custom to balance the work operations. Complied with GLP specifications, meter allows user to carry data statistics, measure results, carry out and review, analyze, and compare statistics.

Conductivity measurement range 0.000 μS/cm to 3000mS/cm
Resistivity measurement range 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range 0.000 mg/L to 1000g/L
Salinity measurement range 0.00 to 8.00 %
Temperature measurement range -5.0 to 135.0 °C
Conductivity accuracy ± 0.5 % FS
Resistivity accuracy ± 0.5 % FS
TDS accuracy ± 0.5 % FS
Salinity accuracy ± 0.1 %
Temperature accuracy ± 0.1  °C
Automatic temperature compensation Yes
Automatic calibration Yes
Automatic range switching Yes
Calibration function Yes
Reading mode <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Timed reading</td> <td style=min-width:50px>Yes</td> </tr> <tr> <td style=min-width:50px>Balanced reading</td> <td style=min-width:50px>Yes</td> </tr> <tr> <td style=min-width:50px>Continuous reading</td> <td style=min-width:50px>Yes</td> </tr> </table>
Data interface RS232, USB
Data storage 1000 sets
Complied with GLP specifications Yes
Power supply (Input: AC 100 to 240 V, 1.35 A) (Output: DC 24 V, 3A)
Dimension 280 × 280 × 130 mm
Weight 2.5 kg
  • 7 inch color touch screen
  • Automatic temperature compensation and calibration
  • Electrode correction function
  • 5 point conductivity calibrations
  • Intelligent operating system
  • 100 sets of measurement data
  • Different conductivity compensation methods (includes pure water)
  • Different salinity compensation methods (includes saline , brine water)
  • Supports USB, RS232 connection with PC, serial printer
  • Supports firmware upgrade, support U disk hot swap
Used to test Conductivity, TDS, Salinity, resistivity values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose.

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop conductivity meter LBCM-A11

Benchtop conductivity meter LBCM-A11

  • Conductivity measurement range
  • 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy
  • ± 1 % F.S.
  • Conductivity resolution
  • 0.01, 0.1, 1
Benchtop Conductivity Meter LBCM-A14

Benchtop Conductivity Meter LBCM-A14

  • Conductivity Mode
  • Conductivity measurement range0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cmConductivity accuracy±1% F.S.Conductivity resolution0.001, 0.01, 0.1, 1Conductivity calibration points1 to 3 pointsConductivity calibration solutions10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
  • TDS Mode
  • TDS measurement Range0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS Accuracy± 1 % F.S.TDS Factor0.01 to 1.00 (default 0.5)TDS Calibration points3 points
  • Temperature Mode
  • Temperature range0 to 105°C, 32 to 221°FTemperature accuracy±1°CTemperature resolution0.1°C, 0.1°FTemperature calibration points1 pointTemperature Compensation Range and ModeManual or Automatic, 0 to 100°C , 32 to 212°FTemperature coefficient0.0 to 10.0 % per °C

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop pH meter LBPM-A20

Benchtop pH meter LBPM-A20

  • pH measurement range
  • -1.00 to 15.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH
Benchtop pH meter LBPM-A11

Benchtop pH meter LBPM-A11

  • pH measurement range
  • 0.00 to 14.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH
Benchtop pH Meter LBPM-B11

Benchtop pH Meter LBPM-B11

  • Temperature compensation
  • 0 to 100°C, 32°F to 212°F Manual or Automatic
  • Hold function
  • Manual or automatic endpoint detection
  • Stability criteria
  • Standard or High-accuracy
Benchtop pH meter LBPM-B10

Benchtop pH meter LBPM-B10

  • pH measurement range
  • -2.000 to 20.000 pH
  • pH accuracy
  • ± 0.002 pH
  • Calibration points
  • 1-5 points

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A11

Benchtop Dissolved oxygen meter LBDO-A11

  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.2 mg / L
  • Resolution
  • 0.01 mg / L
Benchtop Dissolved oxygen meter LBDO-A10

Benchtop Dissolved oxygen meter LBDO-A10

  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.5 mg / L
  • Resolution
  • 0.1 mg / L

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for Cl, LBIM-A10

Benchtop Ion meter for Cl, LBIM-A10

  • Ion measurement range
  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion meter for Cn, LBIM-A21

Benchtop Ion meter for Cn, LBIM-A21

  • Ion measurement range
  • Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion meter for Na, LBIM-A12

Benchtop Ion meter for Na, LBIM-A12

  • Ion measurement range
  • Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion  meter  for K, LBIM-A23

Benchtop Ion meter for K, LBIM-A23

  • Ion measurement range
  • K range: 1×106 - 1M, 0.04 -39000 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10

Benchtop Water hardness meter LBWM-A10

  • Water hardness range
  • 0.05 mmol / L -0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy
  • ± 1 % F.S.
  • Calibration points
  • 2 to 5 points