Benchtop conductivity meter LBCM-A11 is easy to use, it comes with 1 - 3 point calibration system for automatic recognition of the known calibration standards. The LCD display helps to view the measurements and set parameters. The temperature calibration by manual method improves the accuracy of conductivity meter. The system of conductivity meter can set up to 6 parameters like number of calibration points, cell constant etc.

Conductivity measurement range 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy ± 1 % F.S.
Conductivity resolution 0.01, 0.1, 1
Conductivity calibration solutions 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
Conductivity calibration points 1 - 3 points
Temperature compensation range & mode Manual or automatic, 0 to 100 °C , 32 to 212 °F
Temperature range 0 to 105 °C, 32 to 221 °F
Temperature accuracy ± 1°
Temperature resolution 0.1 °C
Temperature coefficient 0.0 to 10.0 % per °C
Cell constant K= 0.1, 1, 10 or User-defined
Data hold function Manual or automatic
Connector 6 - pin mini plug
Display LCD (315 × 75 mm)
Power DC 6 V / 400 mA power adapter, AC 220 V / 50Hz
Dimension (L × W × H) 210 × 205 × 75 mm
Weight 1.5 kg
  • Equipped with white backlit LCD display
  • 1 - 3 point calibration with automatic recognition of calibration solution
  • Manual temperature compensation improves the measurement accuracy of meter
  • Automatic temperature compensation for accurate measured value over the entire range
  • Auto hold function freezes stable, final readings for better viewing and recording
  • Reset function automatically resumes all the settings to default mode
  • System menu allows setting the 6 parameters
  • Automatic power off helps to reduce battery power consumption
  • Help message as an operational guide for Quick access to the conductivity meter
The benchtop conductivity meter is used in water quality analysis, research, education, environmental monitoring, chemicals & liquids quality testing etc. for measuring conductivity.

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Conductivity Meter LBCM-A14

Benchtop Conductivity Meter LBCM-A14

  • Conductivity Mode
  • Conductivity measurement range0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cmConductivity accuracy±1% F.S.Conductivity resolution0.001, 0.01, 0.1, 1Conductivity calibration points1 to 3 pointsConductivity calibration solutions10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
  • TDS Mode
  • TDS measurement Range0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS Accuracy± 1 % F.S.TDS Factor0.01 to 1.00 (default 0.5)TDS Calibration points3 points
  • Temperature Mode
  • Temperature range0 to 105°C, 32 to 221°FTemperature accuracy±1°CTemperature resolution0.1°C, 0.1°FTemperature calibration points1 pointTemperature Compensation Range and ModeManual or Automatic, 0 to 100°C , 32 to 212°FTemperature coefficient0.0 to 10.0 % per °C
Benchtop Conductivity Meter LBCM-A13

Benchtop Conductivity Meter LBCM-A13

  • Conductivity measurement range
  • 0.000 μS/cm to 3000mS/cm
  • Resistivity measurement range
  • 5.00 Ω·cm to 100.0 MΩ·cm
  • TDS measurement range
  • 0.000 mg/L to 1000g/L

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop pH Meter LBPM-B11

Benchtop pH Meter LBPM-B11

  • Temperature compensation
  • 0 to 100°C, 32°F to 212°F Manual or Automatic
  • Hold function
  • Manual or automatic endpoint detection
  • Stability criteria
  • Standard or High-accuracy
Benchtop pH meter LBPM-A11

Benchtop pH meter LBPM-A11

  • pH measurement range
  • 0.00 to 14.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH
Benchtop pH meter LBPM-B10

Benchtop pH meter LBPM-B10

  • pH measurement range
  • -2.000 to 20.000 pH
  • pH accuracy
  • ± 0.002 pH
  • Calibration points
  • 1-5 points
Benchtop pH meter LBPM-A20

Benchtop pH meter LBPM-A20

  • pH measurement range
  • -1.00 to 15.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A10

Benchtop Dissolved oxygen meter LBDO-A10

  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.5 mg / L
  • Resolution
  • 0.1 mg / L
Benchtop Dissolved oxygen meter LBDO-A11

Benchtop Dissolved oxygen meter LBDO-A11

  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.2 mg / L
  • Resolution
  • 0.01 mg / L

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for F, LBIM-A11

Benchtop Ion meter for F, LBIM-A11

  • Ion measurement range
  • F range: 1 × 106M – saturation, 0.02 ppm to saturation
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion  meter  for K, LBIM-A23

Benchtop Ion meter for K, LBIM-A23

  • Ion measurement range
  • K range: 1×106 - 1M, 0.04 -39000 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion meter for NH4, LBIM-A15

Benchtop Ion meter for NH4, LBIM-A15

  • Ion measurement range
  • NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion meter for Cl, LBIM-A10

Benchtop Ion meter for Cl, LBIM-A10

  • Ion measurement range
  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10

Benchtop Water hardness meter LBWM-A10

  • Water hardness range
  • 0.05 mmol / L -0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy
  • ± 1 % F.S.
  • Calibration points
  • 2 to 5 points