Portable Multi-parameter Water Quality Meter LMPWM-A10 is adapted with different modes for measuring quality of water on different parameters such as pH, ORP, Ion, conductivity, TDS, salinity, dissolved oxygen content. Due to its portable design, it is suitable for outdoor measurements i.e. on site water testing, remote area water testing & for research purpose. It is reliable and user friendly.
| pH mode | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>pH measurement range</strong></td><td>(-2.000) to 20.000 pH</td></tr><tr><td><strong>pH accuracy</strong></td><td>± 0.002 pH</td></tr><tr><td><strong>pH calibration points</strong></td><td>1 - 5 points</td></tr><tr><td><strong>pH calibration solutions</strong></td><td>USA, NIST, DIN or user defined</td></tr></table> |
| ORP measurement | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>ORP measurement range</strong></td><td>-1999.9 to 1999.9 mV</td></tr><tr><td><strong>ORP accuracy</strong></td><td>±0.2 mV</td></tr><tr><td><strong>ORP calibration points</strong></td><td>1 point</td></tr><tr><td><strong>ORP calibration solutions</strong></td><td>mV & relative mV</td></tr></table> |
| Ion measurement | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Ion measurement range</strong></td><td>0 to 19999 ppm, mg/L, mol/L</td></tr><tr><td><strong>Ion accuracy</strong></td><td>± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)</td></tr><tr><td><strong>Ion calibration points</strong></td><td>2 - 5 points</td></tr><tr><td><strong>Ion calibration solutions</strong></td><td>0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L</td></tr></table> |
| Conductivity measurement | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Conductivity measurement range</strong></td><td>0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>± 0.5 % F.S.</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 - 5 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm</td></tr><tr><td><strong>Temperature coefficient</strong></td><td>0.0 to 10.0 % / °C</td></tr><tr><td><strong>Compensation modes</strong></td><td>Linear or pre water</td></tr><tr><td><strong>Cell constant</strong></td><td>K = 0.1, 1, 10 or user-defined</td></tr><tr><td><strong>Normalization temperature</strong></td><td>20 °C or 25 °C</td></tr></table> |
| TDS measurement | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>TDS range</strong></td><td>0 to 100 ppt. (max. 200 ppt., depending on factor setting)</td></tr><tr><td><strong>TDS accuracy</strong></td><td>± 1 % F.S.</td></tr><tr><td><strong>TDS factor</strong></td><td>0.1 - 1.0 (default 0.5)</td></tr></table> |
| Salinity measurement | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Salinity range</strong></td><td>0 to 100 ppt. (max. 80 ppt.)</td></tr><tr><td><strong>Salinity accuracy</strong></td><td>± 1 % F.S</td></tr><tr><td><strong>Measurement modes</strong></td><td>Seawater or practical salinity</td></tr></table> |
| Resistivity | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Resistivity range</strong></td><td>0 to 100 Ω</td></tr><tr><td><strong>Resistivity accuracy</strong></td><td>± 1 % F.S</td></tr><tr><td><strong>Resistivity resolution</strong></td><td>0.01, 0.1, 1</td></tr></table> |
| Dissolved oxygen | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>DO concentration range</strong></td><td>0.00 to 20.00 mg/L</td></tr><tr><td><strong>DO accuracy</strong></td><td>± 0.2 mg/L</td></tr><tr><td><strong>Calibration points</strong></td><td>1 - 2 points</td></tr><tr><td><strong>Pressure correction</strong></td><td>60.0 to 112.5 kPa, 450 - 850 mmHg</td></tr><tr><td><strong>Salinity correction</strong></td><td>0 to 50 g/L</td></tr><tr><td><strong>% Saturation of Oxygen</strong></td><td>0.0 to 200.0 %</td></tr><tr><td><strong>Accuracy</strong></td><td>± 2.0 %</td></tr></table> |
| Temperature compensation | 0 to 100 °C, 32 to 212 °F, Manual or Automatic |
| Stability conditions | Low or high |
| Calibration due | 0 to 31 days |
| Memory | Stores up to 500 data sets |
| Output | USB communication interface |
| Dimension (L × W × H) | 185 × 88 × 32 mm |
| Weight | 300 g |
| Power supply | 3 × 1.5 V “AA batteries or DC 5 V power adapter |
Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Popular Categories
Navigation
Contact Us Map