Analytical HPLC System LAHS-A10
Analytical HPLC System LAHS-A10
  • Pump specification: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Type</strong></td><td>Quaternary Low Pressure Pump</td></tr><tr><td><strong>Flow Rate Range</strong></td><td>0.001 to 10.000 ml/min, in 0.001ml increments</td></tr><tr><td><strong>Flow Accuracy</strong></td><td>≤ ± 0.2% (1.00 ml/min, H<sub>2 </sub>O, R.T., 8.5 MPa)</td></tr><tr><td><strong>Flow Precision</strong></td><td>RSD ≤ 0.06% (1.00 ml/min, H<sub>2 </sub>O, R.T., 8.5MPa)</td></tr><tr><td><strong>Maximum Pressure</strong></td><td>63 MPa</td></tr><tr><td><strong>Pressure accuracy</strong></td><td>≤ ± 3.0 %</td></tr><tr><td><strong>Pressure pulsation</strong></td><td>≤ 0.1 MPa</td></tr><tr><td><strong>Composition rang</strong></td><td>0 to 100 %</td></tr><tr><td><strong>Composition precision</strong></td><td>≤ 0.3 % RSD</td></tr></table>
  • UV/VIS Detector: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Wavelength Range</strong></td><td>190 to 800 nm</td></tr><tr><td><strong>Wavelength Repeatability</strong></td><td>≤ 0.1 nm</td></tr><tr><td><strong>Wavelength Accuracy</strong></td><td>≤ ± 1.0 nm</td></tr><tr><td><strong>Band Width</strong></td><td>6 nm</td></tr><tr><td><strong>Response Time</strong></td><td>0.0 s to 5 s</td></tr><tr><td><strong>Baseline Noise</strong></td><td>≤ ± 0.25 × 10<sup>-5 </sup> AU(empty cell, 254 nm, 1.0s)</td></tr><tr><td><strong>Drift</strong></td><td>≤ 0.5 × 10<sup>-4 </sup> AU/h (empty cell, 254 nm, 60 min)</td></tr><tr><td><strong>Path length</strong></td><td>10 mm(analytical cell)</td></tr><tr><td><strong>Light Source</strong></td><td>Deuterium Lamp and Tungsten Lamp</td></tr></table>
  • Data-processing Workstation: System contain the tables for regular samples<br/> Equipped with Internal and external standard calculation process<br/> Automatic display, print, export of data and starting of another program on completion on measurement<br/> Observe with the condition of 21 CFR part 11 directive of the FDA
  • System Kits: 1 Set<br/> Combined A/D converters<br/> Combined vacuum degasser and 4 channel
Analytical HPLC System LAHS-B10
Analytical HPLC System LAHS-B10
  • High Pressure Constant Flow Pump: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Double plunger reciprocating pump</strong></td><td>1 set</td></tr><tr><td><strong>Flow range</strong></td><td>0.001 to 10.00 mL/min</td></tr><tr><td><strong>Setting step size</strong></td><td>0.001 mL/min</td></tr><tr><td><strong>Flow accuracy</strong></td><td>≤ ± 0.3 %</td></tr><tr><td><strong>Flow stability</strong></td><td>RSD ≤ 00.1 %</td></tr><tr><td><strong>Maximum pressure</strong></td><td>42 MPa</td></tr><tr><td><strong>Display pressure error</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Pressure fluctuation</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Power consumption</strong></td><td>80 W</td></tr></table>
  • UV/Visible Detector: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Wavelength range</strong></td><td>190 to 700 nm</td></tr><tr><td><strong>Wavelength repeatability</strong></td><td>± 0.1 nm</td></tr><tr><td><strong>Band width</strong></td><td>8 nm</td></tr><tr><td><strong>Response time</strong></td><td>0 to 4.9 seconds</td></tr><tr><td><strong>Linearity range</strong></td><td>1.8 AU (5 %)</td></tr><tr><td><strong>Baseline Noise</strong></td><td>≤ ± 1 × 10<sup>-5</sup>AU</td></tr><tr><td><strong>Baseline drift</strong></td><td>≤ 2.0 × 10<sup>-4</sup>AU/h</td></tr><tr><td><strong>Minimum detectable concentration</strong></td><td>4.0 × 10<sup>-9</sup> g/mL</td></tr><tr><td><strong>Detector cell</strong></td><td>Optical path: 10 mm<hr> Volume: 10 µL</td></tr><tr><td><strong>Light source</strong></td><td>Deuterium lamp</td></tr><tr><td><strong>Power consumption</strong></td><td>100 W</td></tr><tr><td><strong>Voltage</strong></td><td>AC 110 V/ 220 V ± 10 %, 50/60 Hz</td></tr><tr><td><strong>Packing Dimensions (W × D × H)</strong></td><td>600 × 440 × 380 mm<hr> 2 × (600 × 410 × 300 mm</td></tr><tr><td><strong>Gross weight</strong></td><td>54 kg</td></tr></table>
Analytical HPLC System LAHS-B11
Analytical HPLC System LAHS-B11
  • High Pressure Constant Flow Pump: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Double plunger reciprocating pump</strong></td><td>2 sets</td></tr><tr><td><strong>Flow range</strong></td><td>0.001 to 10.00 mL/min</td></tr><tr><td><strong>Setting step size</strong></td><td>0.001 mL/min</td></tr><tr><td><strong>Flow accuracy</strong></td><td>≤ ± 0.3 %</td></tr><tr><td><strong>Flow stability</strong></td><td>RSD ≤ 00.1 %</td></tr><tr><td><strong>Maximum pressure</strong></td><td>42 MPa</td></tr><tr><td><strong>Display pressure error</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Pressure fluctuation</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Power consumption</strong></td><td>80 W</td></tr></table>
  • UV/Visible Detector: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Wavelength range</strong></td><td>190 to 700 nm</td></tr><tr><td><strong>Wavelength repeatability</strong></td><td>± 0.1 nm</td></tr><tr><td><strong>Band width</strong></td><td>8 nm</td></tr><tr><td><strong>Response time</strong></td><td>0 to 4.9 seconds</td></tr><tr><td><strong>Linearity range</strong></td><td>1.8 AU (5 %)</td></tr><tr><td><strong>Baseline Noise</strong></td><td>≤ ± 1 × 10<sup>-5</sup>AU</td></tr><tr><td><strong>Baseline drift</strong></td><td>≤ 2.0 × 10<sup>-4</sup>AU/h</td></tr><tr><td><strong>Minimum detectable concentration</strong></td><td>4.0 × 10<sup>-9</sup> g/mL</td></tr><tr><td><strong>Detector cell</strong></td><td>Optical path: 10 mm<hr> Volume: 10 µL</td></tr><tr><td><strong>Light source</strong></td><td>Deuterium lamp</td></tr><tr><td><strong>Power consumption</strong></td><td>100 W</td></tr><tr><td><strong>Voltage</strong></td><td>AC 110 V/ 220 V ± 10 %, 50/60 Hz</td></tr><tr><td><strong>Packing Dimensions (W × D × H)</strong></td><td>600 × 440 × 380 mm<hr> 3 × (600 × 410 × 300 mm</td></tr><tr><td><strong>Gross weight</strong></td><td>75 kg</td></tr></table>
Analytical HPLC-A7832
Analytical HPLC-A7832
  • Detector Specifications: <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Model No</td> <td style=min-width:50px>HPD-A20</td> <td style=min-width:50px> HPD-A21</td> </tr> <tr> <td style=min-width:50px>Wavelength range </td> <td style=min-width:50px>Single wavelength ( 190 to 800 nm )</td> <td style=min-width:50px>Dual wavelength ( 190 to 800 nm )</td> </tr> <tr> <td style=min-width:50px>Wavelength accuracy</td> <td style=min-width:50px>± 0.5 nm</td> <td style=min-width:50px>± 2 nm</td> </tr> <tr> <td style=min-width:50px>Wavelength repeatability</td> <td style=min-width:50px>0.15 nm</td> <td style=min-width:50px>0.3 nm</td> </tr> <tr> <td style=min-width:50px>Band width</td> <td style=min-width:50px>8 nm</td> <td style=min-width:50px>8 nm</td> </tr> <tr> <td style=min-width:50px>Optical path</td> <td style=min-width:50px>10 nm</td> <td style=min-width:50px>10 nm</td> </tr> <tr> <td style=min-width:50px>Deuterium lamp</td> <td style=min-width:50px>190 to 400 nm</td> <td style=min-width:50px>190 to 400 nm</td> </tr> <tr> <td style=min-width:50px>Tungsten lamp</td> <td style=min-width:50px>400 to 800 nm</td> <td style=min-width:50px>400 to 800 nm</td> </tr> <tr> <td style=min-width:50px>Baseline noise ( Static ) Au</td> <td style=min-width:50px>≤ ± 0.35 × 10-5</td> <td style=min-width:50px>≤ ± 0.5 × 10-5</td> </tr> <tr> <td style=min-width:50px>Baseline drift ( Static ) Au / h</td> <td style=min-width:50px>≤ 1 × 10-4</td> <td style=min-width:50px>≤ 1.5 × 10-4</td> </tr> <tr> <td style=min-width:50px>Minimum detection limit</td> <td style=min-width:50px>≤ 4 × 10-8</td> <td style=min-width:50px>≤ 4 × 10-8</td> </tr> <tr> <td style=min-width:50px>Power</td> <td style=min-width:50px>100 W</td> <td style=min-width:50px>100 W</td> </tr> <tr> <td style=min-width:50px>Power supply</td> <td style=min-width:50px>90 V / 50 to 60 Hz</td> <td style=min-width:50px>90 V / 50 to 60 Hz</td> </tr> <tr> <td style=min-width:50px>Dimension</td> <td style=min-width:50px>460 × 315 × 180 mm</td> <td style=min-width:50px>460 × 315 × 180 mm</td> </tr> <tr> <td style=min-width:50px>Weight</td> <td style=min-width:50px>9.5 kg</td> <td style=min-width:50px>9.5 kg</td> </tr> </table>
  • Pump Specifications: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Flow rate range</strong></td><td>0.0001 to 10 ml / min</td></tr><tr><td><strong>Maximum pressure</strong></td><td>50 MPa , 0 to 2 ml / min</td></tr><tr><td><strong>Column size</strong></td><td>4.6 × 250 mm</td></tr><tr><td><strong>Sample size</strong></td><td>5 µm</td></tr><tr><td><strong>Pressure pulsation</strong></td><td>≤ 1 % at 10 MPa</td></tr><tr><td><strong>Flow rate accuracy</strong></td><td>± 0.15 % at 1 ml / min</td></tr><tr><td><strong>Flow rate repeatability %</strong></td><td>≤ 0.1</td></tr><tr><td><strong>Gradient accuracy %</strong></td><td>± 1.5</td></tr><tr><td><strong>Gradient repeatability %</strong></td><td>≤ 0.2</td></tr><tr><td><strong>Dimension</strong></td><td>460 × 310 × 180 mm</td></tr><tr><td><strong>Power supply</strong></td><td>90 V</td></tr><tr><td><strong>Weight</strong></td><td>11.6 kg</td></tr></table>
Analytical HPLC-A7835
Analytical HPLC-A7835
  • Pump Specifications: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Model No</strong></td><td>HPP-B1</td></tr><tr><td><strong>Flow rate range</strong></td><td>0.0001 to 10 ml / min</td></tr><tr><td><strong>Maximum pressure</strong></td><td>42 MPa , 0 to 5 ml / min</td></tr><tr><td><strong>Column size</strong></td><td>4.6 × 250 mm</td></tr><tr><td><strong>Sample size</strong></td><td>5 μm</td></tr><tr><td><strong>Pressure pulsation</strong></td><td>≤ 1.5 % at 10 MPa</td></tr><tr><td><strong>Flow rate accuracy</strong></td><td>± 0.2 % at 1 ml / min</td></tr><tr><td><strong>Flow rate repeatability %</strong></td><td>≤ 0.15</td></tr><tr><td><strong>Gradient accuracy %</strong></td><td>± 2</td></tr><tr><td><strong>Gradient repeatability %</strong></td><td>≤ 0.2</td></tr><tr><td><strong>Dimension</strong></td><td>450 × 260 × 190 mm</td></tr><tr><td><strong>Power supply</strong></td><td>90 V to 240 V</td></tr><tr><td><strong>Weight</strong></td><td>11.2 kg</td></tr></table>
  • Detector Specifications: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Model No</strong></td><td>HPD-B2</td></tr><tr><td><strong>Wavelength range</strong></td><td>190 to 800 nm</td></tr><tr><td><strong>Wavelength accuracy</strong></td><td>± 0.75 nm</td></tr><tr><td><strong>Wavelength repeatability</strong></td><td>0.2 nm</td></tr><tr><td><strong>Band width</strong></td><td>8 nm</td></tr><tr><td><strong>Optical path</strong></td><td>10 nm</td></tr><tr><td><strong>Deuterium lamp</strong></td><td>190 to 400 nm</td></tr><tr><td><strong>Tungsten lamp</strong></td><td>400 to 800 nm</td></tr><tr><td><strong>Baseline noise ( Static ) Au</strong></td><td>≤ ± 0.5 × 10 <sup>-5</sup></td></tr><tr><td><strong>Baseline drift ( Static ) Au / h</strong></td><td>≤ 1.5 x 10 <sup>-4</sup></td></tr><tr><td><strong>Minimum detection limit</strong></td><td>≤ 4 x 10 <sup>-8</sup></td></tr><tr><td><strong>Power</strong></td><td>100 W</td></tr><tr><td><strong>Power supply</strong></td><td>90 V / 50 to 60 Hz</td></tr><tr><td><strong>Dimension</strong></td><td>460 × 260 × 190 mm</td></tr><tr><td><strong>Weight</strong></td><td>9.2 kg</td></tr></table>
Analytical HPLC-A7840
Analytical HPLC-A7840
  • Pump Specifications: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Solvent delivery</strong></td><td>Double plunger series mode, floating plunger design, single stroke volume 30 µl</td></tr><tr><td><strong>Pump Head</strong></td><td>10 ml stainless steel pump head</td></tr><tr><td><strong>Flow rate range</strong></td><td>0.001 to 9.999 ml / min</td></tr><tr><td><strong>Flow rate increment</strong></td><td>0.001 ml/min</td></tr><tr><td><strong>Maximum pressure</strong></td><td>42 MPa</td></tr><tr><td><strong>Column size</strong></td><td>4.6 × 250 mm 5 µm</td></tr><tr><td><strong>Pipeline Size</strong></td><td>1/16 inch</td></tr><tr><td><strong>Flow rate accuracy</strong></td><td>± 0.5 %</td></tr><tr><td><strong>Flow rate precision</strong></td><td>RSD ≤ 0.1%</td></tr><tr><td><strong>Gradient accuracy %</strong></td><td>± 0.5 %</td></tr><tr><td><strong>Gradient repeatability %</strong></td><td>RSD ≤ 0.15%</td></tr><tr><td><strong>GLP</strong></td><td>Automatic recording of pump sealing ring working time</td></tr><tr><td><strong>Display</strong></td><td>LCD backlight display</td></tr><tr><td><strong>Power</strong></td><td>80 W</td></tr><tr><td><strong>Power supply</strong></td><td>220 V ± 10%, 50 Hz</td></tr><tr><td><strong>Dimension</strong></td><td>398 × 149 × 267 mm</td></tr></table>
  • Detector Specifications: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Wavelength range</strong></td><td>190 to 700 nm</td></tr><tr><td><strong>Wavelength accuracy</strong></td><td>± 1 nm</td></tr><tr><td><strong>Wavelength repeatability</strong></td><td>0.2 nm</td></tr><tr><td><strong>Deuterium lamp</strong></td><td>190 to 400 nm</td></tr><tr><td><strong>Tungsten lamp</strong></td><td>400 to 700 nm</td></tr><tr><td><strong>Baseline noise ( Static ) Au</strong></td><td>1 × 10<sup>-5</sup> AU/h at 254 nm with methanol/water= 80/20</td></tr><tr><td><strong>Baseline drift ( Static ) Au / h</strong></td><td>1.5 × 10<sup>-4</sup> AU/h at 254 nm with methanol/ water= 80/20</td></tr><tr><td><strong>Time constants</strong></td><td>16 grades adjustable</td></tr><tr><td><strong>Display</strong></td><td>LCD backlight display</td></tr><tr><td><strong>GLP</strong></td><td>Total number of lights, lamp replacement time and product serial number</td></tr><tr><td><strong>Power</strong></td><td>75 W</td></tr><tr><td><strong>Power supply</strong></td><td>220 V ± 10%, 50 Hz</td></tr><tr><td><strong>Dimension (L × W × H)</strong></td><td>398 × 149 × 267 mm</td></tr></table>