Analytical HPLC System LAHS-B10 is a unit equipped with LCD display UV-Visible wavelength range of 190 nm to 700 nm and double plunger reciprocating pump system for constant flow pump. It has isocratic kit system for test result accuracy. Consists of separate workstation, sample injector and front mounted self-locking switch. Deuterium lamp is used as light source with valve mounting frame. It is ideally used in the detection of compounds in pharmaceutical industries, research institute, food industries, and petroleum industries, etc.

High Pressure Constant Flow Pump
Double plunger reciprocating pump1 set
Flow range0.001 to 10.00 mL/min
Setting step size0.001 mL/min
Flow accuracy≤ ± 0.3 %
Flow stabilityRSD ≤ 00.1 %
Maximum pressure42 MPa
Display pressure error≤ 1.0 %
Pressure fluctuation≤ 1.0 %
Power consumption80 W
UV/Visible Detector
Wavelength range190 to 700 nm
Wavelength repeatability± 0.1 nm
Band width8 nm
Response time0 to 4.9 seconds
Linearity range1.8 AU (5 %)
Baseline Noise≤ ± 1 × 10-5AU
Baseline drift≤ 2.0 × 10-4AU/h
Minimum detectable concentration4.0 × 10-9 g/mL
Detector cellOptical path: 10 mm
Volume: 10 µL
Light sourceDeuterium lamp
Power consumption100 W
VoltageAC 110 V/ 220 V ± 10 %, 50/60 Hz
Packing Dimensions (W × D × H)600 × 440 × 380 mm
2 × (600 × 410 × 300 mm
Gross weight54 kg
  • Double plunger reciprocating pump system
  • Isocratic system kits
  • Sample injector: 1 set
  • Deuterium lamp light source
  • Separate workstation
  • LCD display for value observation
  • Front mounted self-locking switch
  • Output: USB port
  • Compact and easy to install
Widely used in pharmaceutical, petroleum, research institute, food industrial applications in separation and detection of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.
No Accessory name
1 Column oven

Standard HPLC

Standard HPLC : HPLC system LHLC-A10

HPLC system LHLC-A10

  • High pressure pump
  • Single pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increment)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-A11

HPLC system LHLC-A11

  • High pressure pump
  • Two sets of pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increments)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-B11
HPLC system LHLC-B11
  • High pressure pump
  • High pressure constant-current infusion pump
  • Infusion Way
  • Micro volume series dual-piston
  • Infusion pressure
  • 0 - 9999 Psi
Standard HPLC : HPLC system LHLC-B10
HPLC system LHLC-B10
  • High pressure pump
  • High pressure gradient pump
  • Peak operating pressure
  • 45 MPa, Stainless steel pump
  • Pressure
  • ± 0.02 MPa

Analytical HPLC

Analytical HPLC : Analytical HPLC-A7840

Analytical HPLC-A7840

  • Pump Specifications
  • Double plunger series mode, floating plunger design, single stroke volume 30 µl
  • Detector Specifications
  • 190 to 700 nm
Analytical HPLC : Analytical HPLC-A7835

Analytical HPLC-A7835

  • Pump Specifications
  • HPP-B1
  • Detector Specifications
  • HPD-B2
Analytical HPLC : Analytical HPLC-A7832
Analytical HPLC-A7832
  • Detector Specifications
  • Model No HPD-A20 HPD-A21 Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm ) Wavelength accuracy ± 0.5 nm ± 2 nm Wavelength repeatability 0.15 nm 0.3 nm Band width 8 nm 8 nm Optical path 10 nm 10 nm Deuterium lamp 190 to 400 nm 190 to 400 nm Tungsten lamp 400 to 800 nm 400 to 800 nm Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5 Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4 Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8 Power 100 W 100 W Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm Weight 9.5 kg 9.5 kg
  • Pump Specifications
  • 0.0001 to 10 ml / min
Analytical HPLC : Analytical HPLC System LAHS-A10
Analytical HPLC System LAHS-A10
  • Pump specification
  • Quaternary Low Pressure Pump
  • UV/VIS Detector
  • 190 to 800 nm
  • Data-processing Workstation
  • System contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA