Soil nutrient tester TSNA-A10 with microprocessor controlled technology measures nutrient values in % and gives accurate test results. Its LCD touch display shows all test parameters, test results, which can be printed out using built-in printer. The optical filter present in the nutrient analyzer acts as light source, its silicon semiconductor acts as signal receiver system with 100000 hours of work life.

Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Wavelength range Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm, Orange light: 590 ± 2 nm
Sensitivity Red light: ≥ 4.5 × 10<sup>-5</sup> , Blue light: ≥ 3.17 × 10<sup>-3</sup> , Green light: ≥ 2.35 × 10<sup>-3</sup> , Orange light: ≥ 2.13 × 10<sup>-3</sup>
Moisture measure range A: humidity 0 to 100 %, B: Accuracy: ±3 %
Measurement time (for soil N, P, K) ≤30 min<br/> 5 pcs soil samples at one time ≤50 min (including pretreatment time)
Soil moisture mode <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Moisture content rate testing range</strong></td><td>0 to 100 %</td></tr><tr><td><strong>Moisture unit</strong></td><td>% (m<sup>3</sup>/m<sup>3</sup>)</td></tr><tr><td><strong>Accuracy</strong></td><td>± 2 %</td></tr></table>
pH mode <table class='table table-striped table-bordered table-responsive'><tr><td><strong>pH Measurement range</strong></td><td>1 to 14 pH</td></tr><tr><td><strong>pH Accuracy</strong></td><td>± 0.1</td></tr></table>
Conductivity mode <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Conductivity Measurement range</strong></td><td>0.01 % to 1.00 %</td></tr><tr><td><strong>Conductivity Accuracy</strong></td><td>± 5 %</td></tr></table>
Dimension 340 × 280 × 100 mm
Gross Weight 15 kg
Power supply AC 180 to 240 V, 50 Hz
  • LCD display touch control
  • Microprocessor controlled technology
  • Built-in thermal printer
  • Automatic temperature calibration system for organic phosphorous testing
  • Excellent shock resistant
  • Digital circuit programmed design
It finds best application in quantitative analysis of to N, P, K, organic matter, pH, trace elements, salinity of soil, fertilizer & other samples.

Soil Testing Instruments

Soil Salinity tester TSST-A10

Soil Salinity tester TSST-A10

  • Salinity Measurement range
  • 0.00 to 19.99 ms/cm
  • Measuring accuracy
  • EC ± 2% full scale
  • Temperature Measurement range
  • -5 to 50°C
Soil nutrient tester TSNA-A11

Soil nutrient tester TSNA-A11

  • Measuring range
  • 0.001 to 9999
  • Stability
  • A (absorbency of light)
  • Linearity error
Soil water hardness meter TSHM-A11

Soil water hardness meter TSHM-A11

  • Maximum load
  • 100 kg ( kg and N can be switched automatically)
  • Resolution
  • 0.01 g
  • Accuracy
  • ± 0.5 %
Soil moisture meter TSMM-A12

Soil moisture meter TSMM-A12

  • Measurement range
  • 0 to 60 %
  • Resolution
  • 0.1
  • Accuracy
  • ± 5 % n (non-saturation condition)

Paper Testing Instruments

Electronic bending stiffness tester TP-E10

Electronic bending stiffness tester TP-E10

  • Testing speed
  • 200° ± 20° / min
  • Test range
  • 1 to 10000 mN
  • Indicating Error
  • ± 1 %
Electronic Tearing tester TP-J21

Electronic Tearing tester TP-J21

  • Capacity
  • 10 -16000 mN
  • Resolution
  • 0.1 mN
  • Tearing arm
  • 104 ± 1 mm
Automatic horizontal tensile tester TP-B11

Automatic horizontal tensile tester TP-B11

  • Sample (size) length
  • 90 to 200 mm
  • Sample width
  • 15 mm, 25 mm, 50mm
  • Measuring range
  • 0 to 30, 0 to 100 N,0 to 300 N
Softness tester TP-H10

Softness tester TP-H10

  • Measuring range
  • 10 to 1000 mN
  • Division value
  • 1 mN
  • Accuracy
  • ± 1%

Plastic Testing Instruments

Oxygen Index Tester TOIT-A10

Oxygen Index Tester TOIT-A10

  • Resolution
  • 0.1 % O2
  • Measuring range
  • 0 to 100 % O2
  • Precision
  • ± 0.4 % O2
Lasting adhesive tester TLAT-A11

Lasting adhesive tester TLAT-A11

  • Standard roller
  • 2000 ± 50 g
  • Testing stations
  • 6
  • Dimension (L*W*H) tester
  • 650×210×550 mm (6 stations)
Heat sealer THS-A10

Heat sealer THS-A10

  • Seal temperature
  • Room temperature -250°C
  • Control accuracy
  • ± 0.2°C
  • Dwell time
  • 0.1 S to 999.9 S
Vacuum Leak Tester TVLT-A10

Vacuum Leak Tester TVLT-A10

  • Vacuum degree
  • 0 to 90 KPa
  • Accuracy
  • 1 % FS
  • Resolution
  • 0.1 KPa

Rubber Testing Instruments

Mooney viscometer TMV-A10

Mooney viscometer TMV-A10

  • Control temperature range
  • Normal temperature to 200°C
  • Temperature display resolution
  • 0.01°C
  • Temperature control accuracy
  • ± 0.3°
Rubber low temperature brittleness tester TRBT-A10

Rubber low temperature brittleness tester TRBT-A10

  • Temperature range
  • -60°C to 0°C
  • Temperature accuracy
  • ± 0.5°C
  • Impact speed
  • 2 m/s ± 0.2 m/s
Rubber-weiss plasticity testing machine TRWM-A10

Rubber-weiss plasticity testing machine TRWM-A10

  • Temperature range
  • RT 50° to 300°
  • Temperature accuracy
  • ± 1°
  • Measuring range
  • 0.01 to 25 mm
DIN abrasion tester TDAT-A10

DIN abrasion tester TDAT-A10

  • Test arm weight
  • 2.5 N
  • Additional Loads
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler
  • 150 mm

NDT Testing Instruments

Rockwell hardness meter TRHM-A10

Rockwell hardness meter TRHM-A10

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 0 to 30 S
Rockwell hardness meter (motorized type) TRHM-B10

Rockwell hardness meter (motorized type) TRHM-B10

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Brinell hardness test
  • 306, 613, 1839 N
Rockwell hardness meter TRHM-A11

Rockwell hardness meter TRHM-A11

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 1 to 30 S
Portable Vibration Calibrator LPVC-A10

Portable Vibration Calibrator LPVC-A10

  • Frequency (continually adjustable)
  • 10 Hz to1280 Hz + 0.01 %
  • Amplitude acceleration ( at 30m/s2 pk )
  • 40 Hz to 320 Hz + 0.3 dB + 1 digit
  • Amplitude velocity ( at 25mm / sec pk )
  • 40 Hz to 320 Hz + 0.5dB +1 digit