Whiteness meter TP-A11 is used to measure the whiteness of objects. Its compact, advanced circuit design ensures the accuracy and stability of measurement data. It measures ISO (R457) whiteness and fluorescence whitening of the materials. The whiteness meter is provided with light absorber to eliminate the influence of specular reflection of the sample.

Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
SystemD/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light sourceD65 as illuminating source
Zero drift≤ 0.1 %
Indication drift≤ 0.1 %
Indication error≤ 0.5 %
Repeatability error≤ 0.1 %
Mirror reflection error≤ 0.1 %
Dimension (L*W*H)360 × 264 × 400 mm
Net weight20 kg
Power supply220 V ± 10 %, 50 Hz
  • Stimulate D65 illuminator to illuminate
  • Adopted with D/0 lighting geometrical viewing conditions
  • Determination of brightness stimulation value
  • Determine the opacity
  • Determination of transparency
  • Determination of light scattering coefficient 'S' and optical absorption coefficient 'A'
  • Measuring ink absorption value
  • Equipped with RS232 interface, with PC connections for data communication
  • Use of large screen color touch LCD to view measurement, statistical data
  • User-friendly data operations
  • Power protection, No loss of data on Power off
Whiteness meter is widely used to measure whiteness in paperboard, textile printing & dyeing, paint, plastic products, ceramic, enamel, detergent, cosmetics.

Paper Testing Instruments

Paper Testing Instruments : Whiteness and chromaticity tester TP-A10

Whiteness and chromaticity tester TP-A10

  • Sample (size) length
  • Diameter ≥30 mm, Thickness ≤ 40 mm
  • Measurement mode
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
  • Stability
  • ≤ 0.1 within 30 min
Paper Testing Instruments : Tensile Stiffness Tester TP-B10

Tensile Stiffness Tester TP-B10

  • Sample (size) length
  • 38×70 mm
  • Measuring range
  • (1-500) mN.m (divided into 7 small ranges)
  • Indication error
  • 0.02
Paper Testing Instruments : Automatic horizontal tensile tester TP-B11
Automatic horizontal tensile tester TP-B11
  • Sample (size) length
  • 90 to 200 mm
  • Sample width
  • 15 mm, 25 mm, 50mm
  • Measuring range
  • 0 to 30, 0 to 100 N,0 to 300 N
Paper Testing Instruments : Automatic horizontal tensile tester TP-B12
Automatic horizontal tensile tester TP-B12
  • Sample (size) length
  • 180 mm (180, 150, 100, 90, 50 mm adjustable)
  • Sample width
  • 15 mm
  • Measuring range
  • 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N

Plastic Testing Instruments

Plastic Testing Instruments : Vicat softening temperature & HDT machine TVHT-A10

Vicat softening temperature & HDT machine TVHT-A10

  • Operating temperature
  • Ambient temperature to 300°C
  • Heating rate
  • 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
  • Maximum temp. error with heating speed
  • ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
Plastic Testing Instruments : Primary adhesive tester TPAT-A10

Primary adhesive tester TPAT-A10

  • Inclined adjustable angle
  • 0 to 40°
  • Panel width
  • 120 mm
  • Test area width
  • 80 mm
Plastic Testing Instruments : Melt flow Indexer TMFI-A10
Melt flow Indexer TMFI-A10
  • Measuring range
  • 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
  • Measuring rate
  • 0.001 S
  • Temperature range
  • 50 to 400°C
Plastic Testing Instruments : Melt flow Indexer TMFI-A11
Melt flow Indexer TMFI-A11
  • Measuring range
  • 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
  • Measuring rate
  • 0.001 S
  • Temperature range
  • 50 to 400°C

Rubber Testing Instruments

Rubber Testing Instruments : DIN abrasion tester TDAT-A10

DIN abrasion tester TDAT-A10

  • Test arm weight
  • 2.5 N
  • Additional Loads
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler
  • 150 mm
Rubber Testing Instruments : Mooney viscometer TMV-A10

Mooney viscometer TMV-A10

  • Control temperature range
  • Normal temperature to 200°C
  • Temperature display resolution
  • 0.01°C
  • Temperature control accuracy
  • ± 0.3°
Rubber Testing Instruments : No rotor rheometer TNRR-A10
No rotor rheometer TNRR-A10
  • Temperature tester
  • Room temperature to 200°C
  • Temperature display resolution
  • 0.1°C
  • Temperature control accuracy
  • ≤ ± 0.3°C
Rubber Testing Instruments : Rubber low temperature brittleness tester TRBT-A10
Rubber low temperature brittleness tester TRBT-A10
  • Temperature range
  • -60°C to 0°C
  • Temperature accuracy
  • ± 0.5°C
  • Impact speed
  • 2 m/s ± 0.2 m/s

NDT Testing Instruments

NDT Testing Instruments : Rockwell hardness meter TRHM-A10

Rockwell hardness meter TRHM-A10

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 0 to 30 S
NDT Testing Instruments : Rockwell hardness meter TRHM-A11

Rockwell hardness meter TRHM-A11

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 1 to 30 S
NDT Testing Instruments : Rockwell hardness meter (motorized type) TRHM-B10
Rockwell hardness meter (motorized type) TRHM-B10
  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Brinell hardness test
  • 306, 613, 1839 N
NDT Testing Instruments : Digital low load Vickers Hardness tester TDVH-A10
Digital low load Vickers Hardness tester TDVH-A10
  • Test force
  • 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
  • Hardness value symbol
  • HV1, HV5, HV10, HV20, HV30, HV250
  • Error range in display
  • ± 3.0 %, ± 2.0 %

Soil Testing Instruments

Soil Testing Instruments : Soil moisture meter TSMM-A10

Soil moisture meter TSMM-A10

  • Measurement range
  • 0 to 80 %
  • Resolution
  • 0.1
  • Accuracy
  • ± 2 % n (non-saturation condition)
Soil Testing Instruments : Soil moisture meter TSMM-A11

Soil moisture meter TSMM-A11

  • Measurement range
  • 0 to 90 %
  • Resolution
  • 0.1 or 0.01
  • Accuracy
  • ± 5 % n (non-saturation condition)
Soil Testing Instruments : Soil moisture meter TSMM-A12
Soil moisture meter TSMM-A12
  • Measurement range
  • 0 to 60 %
  • Resolution
  • 0.1
  • Accuracy
  • ± 5 % n (non-saturation condition)
Soil Testing Instruments : Soil Salinity tester TSST-A10
Soil Salinity tester TSST-A10
  • Salinity Measurement range
  • 0.00 to 19.99 ms/cm
  • Measuring accuracy
  • EC ± 2% full scale
  • Temperature Measurement range
  • -5 to 50°C