Our LKV-A13 is a double layered, desktop structured Kinematic Viscometer which is designed as per ASTM D2171 / D2171M - 10 “Asphalt Kinematic Viscosity Test (Capillary Viscometer Methods”.

Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor 6 W, 1200 rpm
Sample quantity 3 piece at the same time
Bath temperature Ambient temperature ~ 180.0 °C
Measurement range 100 ~ 150 °C or 150 ~ 200 °C
Bath cubage 23 L
Temperature controlling accuracy ± 0.1 °C
Inner capillary viscometer diameters 1.02, 1.26, 1.48, 1.88, 2.20, 3.10 and 4.00 mm
Mercury thermometer scale division 0.1 °C
  • Maximum heating temperature can reach upto135 ℃ (or 180 ℃)
  • High temperature resistant glass bath
  • Electric stirring motor
  • High precision digital temperature controller
It is used in the fields of petroleum & its products industries, research and development department.

Kinematics Viscometer

Kinematics Viscometer LKV-A12

Kinematics Viscometer LKV-A12

  • Ambient temperature
  • (-10) °C ~ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Capillary viscometer
  • 11 pieces
Kinematics Viscometer LKV-A16

Kinematics Viscometer LKV-A16

  • Ambient temperature
  • 0 ~ 40 ºC
  • Relative humidity
  • 20 ~ 90 %, RH while 40 ℃
  • Temperature controlling accuracy
  • ± 0.1 °C
Kinematics Viscometer LKV-A11

Kinematics Viscometer LKV-A11

  • Ambient temperature
  • (-10) °C ~ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Capillary viscometer
  • 11 pieces
Low Temperature Kinematic Viscosity Tester LKV-A14

Low Temperature Kinematic Viscosity Tester LKV-A14

  • Ambient temperature
  • ≤ 30 °C
  • Relative humidity
  • ≤ 85 %
  • Capillary viscometer
  • 13 pieces

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg

Octane Number & Cetane Number Tester

Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max

Acid and Alkali Tester

Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml

Aniline Test Equipment

Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V
Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W