Kinematics Viscometer LKV-A10 is designed with hard glass bath and electric stirring device with 1200 rpm stirring motor. Designed as per ASTM D445 standard configuration, features ambient to 100°C of temperature range and 0 to 9999.9 s of time range. Compact design with RTD PT100 sensor for uniform bath temperature and 6 capillary Pinkevitch viscometer tubes, it is an ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature.

Ambient temperature 15 to 35°C
Relative humidity ≤ 85%
Capillary viscometer 6 capillary Pinkevitch viscometer tubes
Stirring motor 1200 rpm
Temperature range Ambient to 100°C
Temperature accuracy ±0.1℃
Time range 0 to 9999.9 s
Temperature sensor RTD PT100
Capillary viscometer diameter 0.6 mm, 0.8 mm, 1mm, 1.2 mm, 1.5 mm, 2 mm
Bath capacity 12 L
Bath size Φ255×240 mm
Dimension (W×D×H) 500×310×500 mm
Net weight 11.5 kg
  • Hard glass bath, allow personnel to observe liquid flow
  • Electric stirring device with 1200 rpm stirring motor
  • Ambient to 100°C of temperature range and 0 to 9999.9 s of time range
  • RTD PT100 sensor for uniform bath temperature
  • 6 capillary Pinkevitch viscometer tubes with different inner diameters
  • Designed as per ASTM D445 standard configuration
  • An ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature
Kinematics Viscometer is used to measure flow times for a fixed volume of fuel to flow under gravity through a capillary of the viscometer across the fields of petroleum and its products industries, research and development department etc.

Kinematics Viscometer

Kinematics Viscometer LKV-A13

Kinematics Viscometer LKV-A13

  • Ambient temperature
  • (-10) °C ~ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Capillary viscometer
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Kinematics Viscometer LKV-A15

Kinematics Viscometer LKV-A15

  • Ambient temperature
  • (-10) °C ~ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Capillary viscometer
  • 11 pieces
Kinematics Viscometer LKV-A11

Kinematics Viscometer LKV-A11

  • Ambient temperature
  • (-10) °C ~ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Capillary viscometer
  • 11 pieces
Kinematics Viscometer LKV-A16

Kinematics Viscometer LKV-A16

  • Ambient temperature
  • 0 ~ 40 ºC
  • Relative humidity
  • 20 ~ 90 %, RH while 40 ℃
  • Temperature controlling accuracy
  • ± 0.1 °C

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max
Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V