Labtron LAAT-A10 is deliberately fabricated to have high accuracy and easy operation mode. It is constructed as per ASTM-D664 “Test Methods for Water Soluble Acid and Alkali of Petroleum Products”.

Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Ambient temperature (-10 )°C to 35 °C
Relative humidity ≤ 85 %
Test tube Φ18 mm x 100 mm
Acidometer Full scale 0 ~ 14.00 pH
Acidometer Accuracy ± 0.01 pH
Heating power 100 W ~ 1000 W
Total power consumption Not more than 1200 W
Power supply AC 220 V ± 10 %, 50 Hz
Dimension 570 x 540 x 260 mm
  • Heating power can be adjusted continuously
  • Accurate result
  • Easy to control and operate
  • Simple design
It is used to determine water soluble acid and alkali in the liquid petroleum products, additive, lubricating grease, wax and waxy products.

Acid and Alkali Tester

Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml

Octane Number & Cetane Number Tester

Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V

Closed Cup Flash Point Tester

Automatic PMCC Flash Point Tester LCFP-A11

Automatic PMCC Flash Point Tester LCFP-A11

  • Ambient temperature
  • 10 °C ~ 40 °C
  • Relative humidity
  • ≤ 80 %
  • Measurement Range
  • Ambient Temperature ~ 250 °C
PMCC Flash Point Tester LCFP-A10

PMCC Flash Point Tester LCFP-A10

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Temperature range
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Automatic PMCC Flash Point Tester LCFP-A13

Automatic PMCC Flash Point Tester LCFP-A13

  • Ambient temperature
  • 10 °C ~ 40 ℃
  • Relative humidity
  • ≤ 80 %
  • Ignition Mode
  • electron igniter / gas flame