Labtron LKV-A14 Kinematic Viscometer is deliberately designed with advanced compressor refrigeration technology. It is highly efficient and made as per ASTM D445 “Test Methods for Kinematic Viscosity of Petroleum Products and Calculation of Dynamic Viscosity”.

Ambient temperature ≤ 30 °C
Relative humidity ≤ 85 %
Capillary viscometer 13 pieces
Stirring motor 6 W, 1200 rpm
Temperature controlling range Ambient temperature ~ 70 °C
Temperature controlling accuracy ± 0.1 °C
Illumination 6 W / 220 V fluorescent lamp
Constant temperature bath 5.8 L with stainless steel inner tank
Inner capillary viscometer diameters 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0 and 6.0 mm
  • Minimal temperature is (-70) ℃
  • It can do determination for two samples at a time
  • High work efficiency
  • Floor type machine
It is used in the fields of petroleum & its products industries, research and development department.

Kinematics Viscometer

Kinematics Viscometer LKV-A11

Kinematics Viscometer LKV-A11

  • Ambient temperature
  • (-10) °C ~ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Capillary viscometer
  • 11 pieces
Kinematics Viscometer LKV-A13

Kinematics Viscometer LKV-A13

  • Ambient temperature
  • (-10) °C ~ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Capillary viscometer
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Kinematics Viscometer LKV-A15

Kinematics Viscometer LKV-A15

  • Ambient temperature
  • (-10) °C ~ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Capillary viscometer
  • 11 pieces
Kinematics Viscometer LKV-A12

Kinematics Viscometer LKV-A12

  • Ambient temperature
  • (-10) °C ~ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Capillary viscometer
  • 11 pieces

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg

Octane Number & Cetane Number Tester

Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max

Acid and Alkali Tester

Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V