Acid Number Tester LAAT-A12 is automated and controlled by microprocessor unit. It offers 0 to 1800.0 mV potential measurement range and ≥0.05 mg KOH/g acid number measurement range. It works on potentiometric titration principle. Recording the titration of the electrode potential and the titration volume, find out the equivalence point and corresponding titrant volume, and thus obtained the sample pH value. This unit can accurately detect the acid value of transformer oil, turbine oil, anti-oil, diesel, gasoline and other petroleum products. It offers Standard Determination of acid number, Determination of acid number in transformer and turbine oils in service (BTB), ASTM D664-2011).

Measurement range ≥0.05 mg KOH/g
Potential measurement range 0 to 1800.0 mV
Burette volume 10 mL
Minimum titration volume 0.001 ml
Burette precision ±0.1 %FS
Precision Fit or above the relative standards
Ambient temperature 5℃ to 35℃
Relative humidity Less 80 %
Power supply AC (220±11)V , 50±1 Hz
Dimension About 350 × 280 ×178 mm
Net weight Main unit 14 kg
  • Equipped with windows operating platform, with the computer directly
  • Designed with titration curve real-time display, titration curve and data storage and printing
  • Imported titration unit and measuring accuracy better stability
  • Automatic cleaning, automatic constant liquid
  • Offers automatic detection of end points, automatic filtering false end, at the same time can determine the endpoint of artificial selection
  • Designed with continued dosing function
  • It is easy to operate and adopts workstation
Acid Number Tester used in chemical industry, electric power, oil and other industries, it is ideal products to current meter acid number of petroleum products.

Acid and Alkali Tester

Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml

Octane Number & Cetane Number Tester

Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max

Aniline Test Equipment

Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V
Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W

Closed Cup Flash Point Tester

Automatic PMCC Flash Point Tester LCFP-A13

Automatic PMCC Flash Point Tester LCFP-A13

  • Ambient temperature
  • 10 °C ~ 40 ℃
  • Relative humidity
  • ≤ 80 %
  • Ignition Mode
  • electron igniter / gas flame
Automatic PMCC Flash Point Tester LCFP-A11

Automatic PMCC Flash Point Tester LCFP-A11

  • Ambient temperature
  • 10 °C ~ 40 °C
  • Relative humidity
  • ≤ 80 %
  • Measurement Range
  • Ambient Temperature ~ 250 °C
PMCC Flash Point Tester LCFP-A10

PMCC Flash Point Tester LCFP-A10

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Temperature range
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C