ICP Spectrometer LICP-B10 is an instrument which measures elements in ppb levels with least interference and reduces the time taken for analysis by detecting 5 to 6 elements in 1 min. Excellent analytical precision, high optical resolution, fully automated, wide wavelength range with 2400 line grating, powerful analysis software, high performance solid-state RF system, high accuracy etc. are some of the characteristic features. The equipment consist of a Scott-type spray chamber, quartz torch, spectrophotometer with Czerny-Turner monochromator, detector with photomultiplier tube and data processing system which allows multi-element measurement along with high resolution. It finds applications in environmental, food safety, metallurgy, pharmaceutical etc. fields.

Monochromator Specifications <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Optical type</strong></td><td>Czerny turner</td></tr><tr><td><strong>Resolution</strong></td><td>≤ 0.015nm (3600 line grating)<br/> ≤ 0.030nm (2400 line grating)</td></tr><tr><td><strong>Focal length</strong></td><td>1000 mm</td></tr><tr><td><strong>Grating specifications</strong></td><td>huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area</td></tr><tr><td><strong>Wavelength range</strong></td><td>195 to 500 nm for 3600 line grating<br/> 195 to 800 nm for 2400 line grating</td></tr></table>
Solid State Power Specifications <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Frequency</strong></td><td>27.12 MHz<br/> Frequency stability: < 0.05%</td></tr><tr><td><strong>Spray chamber</strong></td><td>Scott double pass spray chamber</td></tr><tr><td><strong>Output power</strong></td><td>800 W to 1600 W, adjustable with power efficiency more than 65%</td></tr><tr><td><strong>Output power stability</strong></td><td>≤ 0.05%</td></tr><tr><td><strong>Induction coil</strong></td><td>25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)</td></tr></table>
Technical Specifications <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Suitable sample content range</strong></td><td>Liquid sample: 0.01 ppm to several thousand ppm<br/> Solid or power sample: 0.001% to 70%</td></tr><tr><td><strong>Repeatability</strong></td><td>short-term stability- RSD ≤ 1.5%<br/> Long-term stability: RSD ≤ 2%</td></tr><tr><td><strong>Test speed</strong></td><td>5 to 8 elements / min</td></tr><tr><td><strong>Limits of detection (LOD, µg/L) for most elements</strong></td><td>1ppb to 10ppb</td></tr></table>
Control Circuit <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Photomultiplier tube specification</strong></td><td>R212 / R928</td></tr><tr><td><strong>Negative high voltage</strong></td><td>-50 to -1000 V</td></tr><tr><td><strong>Circuit measuring range</strong></td><td>(10<sup>-12</sup> to 10 <sup>-4</sup>) A</td></tr><tr><td><strong>Signal acquisition</strong></td><td>VF conversion</td></tr></table>
Working Environment <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Temperature for storage and transportation</strong></td><td>15°C to 25°C</td></tr><tr><td><strong>Humidity for storage and transportation</strong></td><td>≤ 70%</td></tr><tr><td><strong>Power Stability</strong></td><td>220 ± 10V; 50 to 60 V</td></tr><tr><td><strong>Humidity</strong></td><td>≤ 70%</td></tr><tr><td><strong>Temperature</strong></td><td>15°C to 30°C</td></tr></table>
Other Details <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Packaging Dimension and Gross Weight (4 case)</strong></td><td>1st case: 188 × 111 × 105 / 348 kg<br/> 2nd case: 60 × 60 × 55 / 25 kg<br/> 3rd case: 59 × 67 × 97 / 80 kg<br/> 4th case: 38.5 × 38.5 × 63 / 47 kg</td></tr></table>
  • Highly advance optical design
  • Holographic grating for minimum scattering of light
  • Correction of spectral interference to improvise detection
  • System controlled torch movement for optimized position
  • System controlled mass flow controller for carrier gas, auxiliary gas and plasma gas
  • 27.12 MHz RF generator for efficient ionization
  • Auto-coupling system
  • Peristaltic pump for stable flow rate and drainage of sample
  • Argon gas cylinder last up to 8 hours
  • Auto-sampler can be provided
  • Software Details
  • Allows selection of multiple elements and parameters for analysis
  • Faster Calibration function
  • Correction of background interference
  • Report generation with single button press
  • Many export options
  • Real-time graphical display of instrument status
  • Plasma ignition with one button press
  • Large database to select spectral lines according to requirement
It used for quantitative and qualitative analysis of elements in the given sample. Various fields like petrochemicals, pharmaceuticals, agriculture, environmental, food industry, metallurgy, processing industry etc. require it for several operations.

ICP Spectrometer

ICP Spectrometer LICP-A11

ICP Spectrometer LICP-A11

  • Wavelength range
  • 180 to 900 nm
  • Elements per minute
  • 15 elements
  • Temperature
  • 29 °C
ICP spectrometer LICP-A10

ICP spectrometer LICP-A10

  • Wavelength range ( 3600 lines / mm )
  • 180 to 500 nm
  • Wavelength range ( 2400 lines / mm )
  • 180 to 800 nm
  • Temperature
  • 20 ~ 28 °C

FTIR Spectrometer

FTIR Spectrometer LIR-B10

FTIR Spectrometer LIR-B10

  • Spectral Range
  • 7800 cm-1 to 350 cm-1
  • Resolution
  • 0.85 cm-1
  • Wave number precision
  • ± 0.01 cm-1

Atomic Fluorescence Spectrometer

Atomic Fluorescence Spectrometer LAFS-A10

Atomic Fluorescence Spectrometer LAFS-A10

  • Beam Configuration
  • Dual Channel
  • Elements ( Measuring Range )
  • As, Se, Pb, Bi, Sb, Te, Sn< 0.01 µg/LHg, Cd< 0.001 µg/LZn< 1.0 µg/LGe< 0.1 µg/L
  • Precision ( RSD )
  • < 1.0

XRF Spectrometer

Handheld XRF Spectrometer LXRF-B10

Handheld XRF Spectrometer LXRF-B10

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector
XRF-Spectrometer LXRF-A10

XRF-Spectrometer LXRF-A10

  • Measureable elements
  • S to U
  • Detection limit
  • 1 ppm
  • Temperature
  • 15 ~ 30 °C
Handheld XRF Spectrometer LXRF-B11

Handheld XRF Spectrometer LXRF-B11

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector

XRD Diffractometer

XRD Diffractometer LXRD-A10

XRD Diffractometer LXRD-A10

  • X-ray Tuble
  • Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
  • Focus Size
  • 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
  • Stability
  • ≤ 0.01 %