ICP Spectrometer LICP-A11 detects micro and macro elements using argon plasma with an analyzing rate of 15 elements per minute. Results can be achieved with lower levels of detection for qualitative and quantitative analysis. Detection of liquid flow from the spray chamber by optical drain sensor offers exceptional sensitivity and accuracy. Accurate signal-background ratio is attained by advanced control system.

Wavelength range 180 to 900 nm
Elements per minute 15 elements
Temperature 29 °C
Incident slit 25 µm
Standard deviation RSD ≤ 2 %
Correlation coefficient ≥ 0.9995 %
Gas source Argon ( 99.99 % )
Plasma gas flow meter 100 – 1000 L / h ( 1.6 - 16 L / min )
Auxillary gas flow meter 10 – 100 L / h ( 0.16 – 1.66 L / min )
Carrier gas flow meter 0 ~ 5 L / min
Cooling water flow rate 5 L / min
Cooling water temperature 20 ~ 26 °C
Water outlet diameter 10 mm
Line dispersion rate 0.26 nm
Resolving power ≤ 0.007 nm
Co-axial sprayer diameter 6 mm
Coil diameter 25 mm
Double room fog diameter 34 mm
Quartz tube torch diameter 20 mm
Mirror dimensions 80 x 110 x 16 mm
  • Rapid analysis – 15 elements per minute
  • Optical pathway – Czerny-turners
  • Low detection limit
  • Detection of multi-elements including non-metallic
  • Single and multi-element measurement method
  • Indication for wavelength error and repeatability
  • Range of measurement – common to trace
Used in clinical analysis for detection of metals in biological fluids , environmental analysis for trace element detection in water , soil , plants , pharmaceuticals for traces of catalysts and poison metals like Cd , Pb , industries for noble metal detection

ICP Spectrometer

ICP Spectrometer LICP-B10

ICP Spectrometer LICP-B10

  • Monochromator Specifications
  • Optical typeCzerny turnerResolution≤ 0.015nm (3600 line grating) ≤ 0.030nm (2400 line grating)Focal length1000 mmGrating specificationshuge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling areaWavelength range195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating
  • Solid State Power Specifications
  • Frequency27.12 MHz Frequency stability: < 0.05%Spray chamberScott double pass spray chamberOutput power800 W to 1600 W, adjustable with power efficiency more than 65%Output power stability≤ 0.05%Induction coil25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
  • Technical Specifications
  • Suitable sample content rangeLiquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%Repeatabilityshort-term stability- RSD ≤ 1.5% Long-term stability: RSD ≤ 2%Test speed5 to 8 elements / minLimits of detection (LOD, µg/L) for most elements1ppb to 10ppb
ICP spectrometer LICP-A10

ICP spectrometer LICP-A10

  • Wavelength range ( 3600 lines / mm )
  • 180 to 500 nm
  • Wavelength range ( 2400 lines / mm )
  • 180 to 800 nm
  • Temperature
  • 20 ~ 28 °C

FTIR Spectrometer

FTIR Spectrometer LIR-B10

FTIR Spectrometer LIR-B10

  • Spectral Range
  • 7800 cm-1 to 350 cm-1
  • Resolution
  • 0.85 cm-1
  • Wave number precision
  • ± 0.01 cm-1

Atomic Fluorescence Spectrometer

Atomic Fluorescence Spectrometer LAFS-A10

Atomic Fluorescence Spectrometer LAFS-A10

  • Beam Configuration
  • Dual Channel
  • Elements ( Measuring Range )
  • As, Se, Pb, Bi, Sb, Te, Sn< 0.01 µg/LHg, Cd< 0.001 µg/LZn< 1.0 µg/LGe< 0.1 µg/L
  • Precision ( RSD )
  • < 1.0

XRF Spectrometer

Handheld XRF Spectrometer LXRF-B11

Handheld XRF Spectrometer LXRF-B11

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector
Handheld XRF Spectrometer LXRF-B10

Handheld XRF Spectrometer LXRF-B10

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector
XRF-Spectrometer LXRF-A10

XRF-Spectrometer LXRF-A10

  • Measureable elements
  • S to U
  • Detection limit
  • 1 ppm
  • Temperature
  • 15 ~ 30 °C

XRD Diffractometer

XRD Diffractometer LXRD-A10

XRD Diffractometer LXRD-A10

  • X-ray Tuble
  • Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
  • Focus Size
  • 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
  • Stability
  • ≤ 0.01 %