ICP spectrometer LICP-A10 detects trace elements using argon plasma where the atomized liquid sample is injected. With an analyzing rate of 26 elements per minute results can be achieved with lower levels of detection and measurement of trace and ultra-trace elements. Elements can be traced from liquid and solid samples. Detection of liquid flow from the spray chamber by optical drain sensor offers exceptional sensitivity and accuracy.

Wavelength range ( 3600 lines / mm ) 180 to 500 nm
Wavelength range ( 2400 lines / mm ) 180 to 800 nm
Temperature 20 ~ 28 °C
Elements per minute 26 elements
Humidity 70%
Focal length 1000 mm
Standard deviation RSD ≤ 1.0 %
Correlation coefficient ≥ 0.9998
Gas source Argon ( 99.99 % )
Plasma gas flow meter 100 ~ 1000 L / h
Auxillary gas flow meter 10 ~ 100 L / h
Carrier gas flow meter 10 ~ 100 L / h
Cooling water flow rate 5 liters per min
Cooling water temperature 21 ~ 26 °C
Water outlet diameter Ø 10 mm
Line dispersion rate 0.26 nm
Resolving power ≤ 0.008 nm
Incident slit 20 µm
Co-axial sprayer diameter 6 mm
Coil diameter 25 mm ( 3 turn )
Double room fog diameter 34 mm
Quartz tube torch diameter 20 mm
Mirror dimensions 78 x 105 x 16 mm
  • Scanning range variance ( 190 nm to 500 nm / 190 nm to 800 nm )
  • Rapid analysis – 26 elements per minute
  • Temperature range – 20 to 28 °C
  • Optical pathway – Czerny-turners
  • Low detection limit
  • Detection of multi-elements including non-metallic
  • Single and multi-element measurement method
  • Indication for wavelength error and repeatability
  • Range of measurement – common to trace
Used in clinical analysis for detection of metals in biological fluids , environmental analysis for trace element detection in water , soil , plants , pharmaceuticals for traces of catalysts and poison metals like Cd , Pb , industries for noble metal detection

ICP Spectrometer

ICP Spectrometer LICP-A11

ICP Spectrometer LICP-A11

  • Wavelength range
  • 180 to 900 nm
  • Elements per minute
  • 15 elements
  • Temperature
  • 29 °C
ICP Spectrometer LICP-B10

ICP Spectrometer LICP-B10

  • Monochromator Specifications
  • Optical typeCzerny turnerResolution≤ 0.015nm (3600 line grating) ≤ 0.030nm (2400 line grating)Focal length1000 mmGrating specificationshuge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling areaWavelength range195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating
  • Solid State Power Specifications
  • Frequency27.12 MHz Frequency stability: < 0.05%Spray chamberScott double pass spray chamberOutput power800 W to 1600 W, adjustable with power efficiency more than 65%Output power stability≤ 0.05%Induction coil25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
  • Technical Specifications
  • Suitable sample content rangeLiquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%Repeatabilityshort-term stability- RSD ≤ 1.5% Long-term stability: RSD ≤ 2%Test speed5 to 8 elements / minLimits of detection (LOD, µg/L) for most elements1ppb to 10ppb

FTIR Spectrometer

FTIR Spectrometer LIR-B10

FTIR Spectrometer LIR-B10

  • Spectral Range
  • 7800 cm-1 to 350 cm-1
  • Resolution
  • 0.85 cm-1
  • Wave number precision
  • ± 0.01 cm-1

Atomic Fluorescence Spectrometer

Atomic Fluorescence Spectrometer LAFS-A10

Atomic Fluorescence Spectrometer LAFS-A10

  • Beam Configuration
  • Dual Channel
  • Elements ( Measuring Range )
  • As, Se, Pb, Bi, Sb, Te, Sn< 0.01 µg/LHg, Cd< 0.001 µg/LZn< 1.0 µg/LGe< 0.1 µg/L
  • Precision ( RSD )
  • < 1.0

XRF Spectrometer

Handheld XRF Spectrometer LXRF-B11

Handheld XRF Spectrometer LXRF-B11

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector
Handheld XRF Spectrometer LXRF-B10

Handheld XRF Spectrometer LXRF-B10

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector
XRF-Spectrometer LXRF-A10

XRF-Spectrometer LXRF-A10

  • Measureable elements
  • S to U
  • Detection limit
  • 1 ppm
  • Temperature
  • 15 ~ 30 °C

XRD Diffractometer

XRD Diffractometer LXRD-A10

XRD Diffractometer LXRD-A10

  • X-ray Tuble
  • Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
  • Focus Size
  • 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
  • Stability
  • ≤ 0.01 %