Automatic Distillation Apparatus LADA-A10 is a benchtop unit which can automatically determine the distillation range of petroleum products. Test procedures like heating, distillation speed and recording the data are fully automated. Large LCD display and easy to handle operations makes it highly convenient to use. It complies with ASTM D86 and IP123 standards.

Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Refrigeration temperature 0 to 60℃
Refrigeration accuracy ± 1℃
Temperature measurement accuracy ± 0.1℃
Volume accuracy ± 0.1 ml
Power AC 220 V ± 10% 50 Hz
  • 10'' LCD touch screen to view and pre-set several parameters
  • Highly advance level tracking system with American Haydon high-stepping linear motor
  • Imported integral linear ball screw circumferential positioning laser tracker
  • Imported Danfoss (Secop) Compressor
  • Mechanically refrigerated cooling tube and cylinder room
  • Automatic heating control (distillation process): up to 95% sample heating control with controlled flow rate of 4 to 5 ml/min
  • Display shows initial and final boiling point temperature, various % temperature and flow rate
  • Automatic correction of local atmospheric pressure to standard atmospheric pressure
  • Test process is stopped by temperature of steam
  • Results can be stored and printed
It is widely used to determine the distillation range of various petroleum products in laboratories, research institutes and industries.

Distillation Tester

Distillation Tester (low temperature single unit) LDT-A17

Distillation Tester (low temperature single unit) LDT-A17

  • Graduated flasks
  • 100 ml
  • Distillation flask
  • 125 mL
  • Ambient temperature
  • ≤ 30 °C
Vacuum Distillation Tester LDT-A13

Vacuum Distillation Tester LDT-A13

  • Ambient temperature
  • 5 °C to 35 ℃
  • Relative humidity
  • ≤ 85 %
  • Cubage of buffer vessel
  • 1000 ml
Distillation Tester (low temperature Double units) LDT-A16

Distillation Tester (low temperature Double units) LDT-A16

  • Graduated flasks
  • 100 ml
  • Distillation flask
  • 125 ml
  • Ambient temperature
  • ≤ 35 °C
Distillation Tester LDT-A12

Distillation Tester LDT-A12

  • Graduated flasks
  • 100 ml
  • Scale division of graduated flask
  • 1 ml
  • Outer diameter of distillation flask
  • φ65

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max
Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V