Distillation Tester Front Type LDT-A14 is a desktop structure model with adjustable heating power. It is designed according to (Test Methods for Distillation Characteristics of Petroleum Products at Barometric Pressure) as per ASTM D86.

Distillation flask 125 mL
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Thermometer (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Division value 1℃
Receiving cylinder 100 ml
Scale division 1 ml
Dimension 620 × 510 × 620 mm
Heating power system 1000 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Desktop structure
  • Flexible and convenient to operatebr/>
  • Special heating furnace to ensure the safety measurementbr/>
  • Adjustable heating powerbr/>
  • Lifting device for easy operation
It is used to determine distillation characteristics of natural gasoline, vehicle gasoline, aviation gasoline, jet fuels, naphtha, diesel oil and similar petroleum products.

Distillation Tester

Distillation Tester (low temperature Double units) LDT-A16

Distillation Tester (low temperature Double units) LDT-A16

  • Graduated flasks
  • 100 ml
  • Distillation flask
  • 125 ml
  • Ambient temperature
  • ≤ 35 °C
Distillation Tester Dual Units LDT-A15

Distillation Tester Dual Units LDT-A15

  • Graduated flasks
  • 100 ml
  • Scale division of graduated flask
  • 1ml
  • Distillation flask
  • 125 ml
Benzene Distillation Tester (Low Temperature) LDT-A11

Benzene Distillation Tester (Low Temperature) LDT-A11

  • Ambient temperature
  • -10°C to 35°C
  • Relative humidity
  • ≤ 85 %
  • Thermometer
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Vacuum Distillation Tester LDT-A13

Vacuum Distillation Tester LDT-A13

  • Ambient temperature
  • 5 °C to 35 ℃
  • Relative humidity
  • ≤ 85 %
  • Cubage of buffer vessel
  • 1000 ml

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg

Octane Number & Cetane Number Tester

Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V