LWT-B10 is crafted to determine water content in crude petroleum according to ASTM D4006 “Test Methods for Water Content of Crude Petroleum” international standard.

Ambient Temperature (-10) °C ~ 35 °C
Relative Humidity ≤ 85 %
Distillation flask 1000 ml
Water receiver 5 ml
scale division 0.05 ml
Condenser 400 mm ± 5 mm
Dimensions 820 × 500 × 260 mm
Power Supply AC 220 V ± 10 %, 50 Hz
  • Simple Design
  • Adjustable Electric Heating Power
  • Adopts Heating Mantle
It is used to determine water content in crude oil, refined petroleum products, fuels, biofuels, lubricants, chemicals, and other products 

Water Content Tester

Coulometric Karl Fischer Titrator LWT-A30

Coulometric Karl Fischer Titrator LWT-A30

  • Ambient Temperature
  • 10°C to 35°C
  • Measurement Range
  • 0 to 100 mg
  • Resolution
  • 0.1 µg
Water Content Tester LWT-A10

Water Content Tester LWT-A10

  • Ambient Temperature
  • ≤ 35 °C
  • Relative Humidity
  • ≤ 85 %
  • Heating Power of Electric Furnace
  • 1000 W
Coulometric Karl Fischer Titrator LWT-A31

Coulometric Karl Fischer Titrator LWT-A31

  • Maximum current
  • 400 mA
  • Measurement range
  • 3 µg to 9999.9 µg
  • Resolution
  • 0.1 µg
Water Content Tester LWT-A11

Water Content Tester LWT-A11

  • Ambient Temperature
  • ≤ 35 °C
  • Relative Humidity
  • ≤85 %
  • Heating Power of Electric Furnace
  • 1000 W × 2

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max
Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON

Acid and Alkali Tester

Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V