Penetrometer LMPT-A12 is a two grade low temperature controlled unit for determining penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt with time control. It has digital display which shows penetration number of sample. Separate automatic low temperature circulatory water bath for maintaining constant temperature on the unit. It is ideally used for different types of asphalt, food industries, highway engineering, etc.

Penetrometer <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Measurement range</strong></td><td>0 to 600 penetration scale</td></tr><tr><td><strong>Timing controller</strong></td><td>5 sec or 60 sec</td></tr><tr><td><strong>Time accuracy</strong></td><td>± 0.1 seconds</td></tr><tr><td><strong>Resolution</strong></td><td>0.1 penetration</td></tr><tr><td><strong>Penetration accuracy</strong></td><td>± 1 penetration</td></tr><tr><td><strong>Weight of standard needle</strong></td><td>2.5 ± 0.05 g</td></tr><tr><td><strong>Dimensions (W × L × H)</strong></td><td>700 × 400 × 750 mm</td></tr><tr><td><strong>Weight</strong></td><td>30 kg</td></tr></table>
Circulatory Water Bath <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Bath volume</strong></td><td>3.5 L</td></tr><tr><td><strong>Temperature range</strong></td><td>5 °C to 60 °C</td></tr><tr><td><strong>Temperature accuracy</strong></td><td>± 0.1 °C</td></tr><tr><td><strong>Circulatory water quantity</strong></td><td>3 L/minute</td></tr><tr><td><strong>Pump Lift</strong></td><td>2 m</td></tr><tr><td><strong>Power consumption</strong></td><td>1200 W</td></tr><tr><td><strong>Power supply</strong></td><td>AC 220V ± 10 %, 50 Hz</td></tr><tr><td><strong>Dimensions (W × L × H)</strong></td><td>600 × 400 × 650 mm</td></tr><tr><td><strong>Weight</strong></td><td>40 kg</td></tr></table>
  • Digital display shows penetration number of the sample
  • Two grade of timing control
  • Adjustable needle holder
  • Designed for low temperature measurement
  • Circulatory water bath maintains constant temperature
  • Low temperature can be preset for different specimens
Widely used for determining needle penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt, also for solid particle, powder, colloid mixture, highway engineering and food materials such as glycine, cheese, butter, cream, leavening agents, etc.

Penetrometer

Penetrometer LMPT-A11

Penetrometer LMPT-A11

  • Measurement range
  • 0 to 600 penetration scale
  • Timing controller
  • 5 sec or 60 sec
  • Time accuracy
  • ± 0.1 seconds
Penetrometer LMPT-A10

Penetrometer LMPT-A10

  • Measurement range
  • 0 to 600 penetration scale
  • Timing controller
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
  • Time accuracy
  • ± 0.1 seconds
Penetrometer LMPT-A13

Penetrometer LMPT-A13

  • Measurement range
  • 0 to 600 penetration scale
  • Timing range
  • 0 sec to 60 sec
  • Time accuracy error
  • ≥ ± 0.1 seconds

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max
Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON

Acid and Alkali Tester

Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V