Labtron LBC-C21 is designed with high precision sensor and microprocessor to get reliable and accurate results. It is designed and made as per the International Standards ASTM D5865-13 “Test Methods for Heat of Coal”, ASTM D240-17 “Test Methods for Calorific Value of Petroleum Products” and ASTM D4809-13“Oxygen Bomb Calorimeter”.

Temperature controlling range 10 ℃ ~ 35 ℃
Temperature resolution 0.001 ℃
Mean value of heat capacity 15 kJ / K
Ambient temperature 20 ℃ ± 5 ℃
Relative humidity ≤ 85 %
Endured pressure of oxygen bomb 20 MPa Test pressure in oxygen bomb: 3 MPa
Temperature saved 31 pieces
Measurement accuracy for heat value ≤ 0.2 %
Dimension 400 × 400 × 600 mm
weight 18 kg
  • High precision sensor
  • Accurate and reliable
  • Microprocessor for control and led for display
  • Stirring motor has no noise
  • Easy transportation
It is mainly used in petroleum, chemical, automobile and development industries. It is suitable for determining heat value of petroleum products (Gasoline, jet fuels, diesel oil and fuel oils), which do not contain water, coal, paraffin and other combustible substance.

Oxygen Bomb Calorimeter

Oxygen Bomb Calorimeter LBC-C20

Oxygen Bomb Calorimeter LBC-C20

  • Heat capacity
  • 14000 ~ 15000 J / K
  • Temperature measurement range
  • 10 ~ 35 ℃
  • Repeatability error
  • ≤ 0.2 % (Grade C)
Oxygen Bomb Calorimeter LBC-C22

Oxygen Bomb Calorimeter LBC-C22

  • Temperature measurement range
  • 10 ~ 35 ℃
  • Repeatability error
  • ≤ 0.2 % (Grade C)
  • Endured pressure in oxygen bomb
  • 20 MPa

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg

Octane Number & Cetane Number Tester

Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max

Acid and Alkali Tester

Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V