Oxidation Stability Tester (Lubricating Grease) LOST-D20 is a benchtop unit and offers temperature range of 150°C with precision of ± 0.1°C. Easy to use, safe, reliable and is a small size tester, occupies less space. It is applicable for determination of oxidation stability of grease by oxygen bomb method.

Temperature Range Ambient to 150℃
Temperature Precision ± 0.1°C
Test Unit 2 units
Heating Power 1800 W
Ambient Temperature (Room temperature to 35°C
Relative Humidity ≤ 85 %
Power Supply AC (220 ± 10 %) V, 50 Hz
  • Easy to maintain and operate
  • Double test unit and integrated design
  • Equipped with stability and high temperature control precision
  • Convenient for parallel experiments
  • Integrated, automatic timing with alarm prompt system
  • Built-in PID temperature control technology
Oxidation Stability Tester is primarily used in quality control, petroleum, chemical research, university and power. It is also used in testing of lubricant oil, fuel oil and crude oil.

Oxidation Stability Tester

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • Samples
  • 2
  • Oil bath cubage
  • 30 L
  • Angle between bomb and water surface
  • 30 °
Distillate Fuel Oil Oxidation Stability Tester LOST-D12

Distillate Fuel Oil Oxidation Stability Tester LOST-D12

  • Samples
  • 8
  • Temperature
  • 100 ℃
  • Temperature controlling accuracy
  • 0.1 ℃
Transformer Oil Oxidation Stability Tester LOST-D11

Transformer Oil Oxidation Stability Tester LOST-D11

  • Samples
  • 6
  • Temperature controlling mode
  • Automatic digital temperature
  • Temperature controlling range
  • Room temperature ~ 160 °C
Gasoline Oxidation Stability Tester LOST-D13

Gasoline Oxidation Stability Tester LOST-D13

  • Type
  • Compact; Desktop
  • Design
  • Integrated
  • Bath
  • Metal bath (without water usage)

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max
Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON

Acid and Alkali Tester

Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV

Aniline Test Equipment

Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V
Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W