Labtron LOFP-A10 is designed with higher precision and perfection to meet its wide range of applications. It is incorporated with advanced and reasonable temperature control features.

Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Outer Crucible-Material Carbon structural steel
Outer Crucible-Diameter Of Upper Opening Φ100 ± 5 mm
Outer Crucible-Height 50 ± 5 mm
Outer Crucible-Diameter Of Bottom Φ56 ± 2 mm
Inner Crucible-Material Carbon structural steel
Inner Crucible-Diameter Of Upper Opening Φ64 ± 1 mm
Inner Crucible-Height 47 ± 1 mm
Inner Crucible-Diameter Of Bottom Φ38± 1 mm
Inner Crucible-Scale Line 12mm away from the rim of upper opening and 18mm away from the rim of upper opening
Gas Tube Φ0.8 ~ Φ1 mm
Flame 3 to 4 mm
Heater Heated by an electric furnace
Heating Power 1000W
Dimensions 410 x 360 x 240 mm
Power Consumption ≤ 1100 W
Power Supply AC 220 V ± 10 %, 50Hz
  • Adjustable heating power
  • Electric current meter to display power
  • Tiny desktop structure
  • Easy to operate
Used to determine the flash point and fire point of lubricating oil and dark petroleum products

Open Cup Flash Point Tester

Cleveland Open Cup Flash Point Tester LOFP-A11

Cleveland Open Cup Flash Point Tester LOFP-A11

  • Thermometer
  • 6 ℃ ~ 400 ℃
  • Scale Division
  • 2 °C
  • Spout Aperture
  • 0.6 ~ 0.8 mm
Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

  • Ambient Temperature
  • 10 ℃ ~ 40 °C
  • Relative Humidity
  • ≤ 80 %
  • Temperature Measurement- Full Scale
  • Ambient temperature to 300 °C
Automatic COC Flash & Fire Point Tester LOFP-B10

Automatic COC Flash & Fire Point Tester LOFP-B10

  • Ambient Temperature
  • 10 ℃ ~ 40 ℃
  • Relative Humidity
  • ≤ 85 %
  • Temperature Measurement- Full Scale
  • Ambient temperature to ~ 400 ℃

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg

Octane Number & Cetane Number Tester

Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max

Acid and Alkali Tester

Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml

Aniline Test Equipment

Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V
Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W