Pour and Cloud Point Tester LLTT-A14 is a concise designed unit, made as per ASTM D97,ASTM D2500, ASTM D5853 Standard Test Method for Pour Point of Petroleum Oils and ASTM D5773, Standard Test Method of Cloud Point of Petroleum Products. Features two cooling bath chambers with temperature controller, ensures fast and high cooling efficiency. Equipped with new type of refrigeration compressor, the temperature of both cooling bath is same with ±1°C precision. With benchtop structure and easy usage, this pour and cloud point tester is suitable to determine pour point and cloud point of petroleum oils.

Chamber quantity 2 chambers
Chamber 01 temperature control Ambient to -51 ℃
Chamber 02 temperature control Ambient to -65 ℃
Temperature precision ±1°C
Ambient temperature ≤ 30°C
Relative humidity ≤ 85%
Refrigeration system New type refrigeration compressor
Power supply AC 220 V± 10%, 50 Hz
Power 1500 W
Dimension (L×W×H) 800×580×400 mm
Weight 32 kg
  • Concise designed unit with benchtop structure
  • Made as per ASTM D97,ASTM D2500, ASTM D5853 Standard Test Method for Pour Point of Petroleum Oils
  • Designed as per ASTM D5773, Standard Test Method of Cloud Point of Petroleum Products
  • Two cooling bath chambers with temperature controller and new type of refrigeration compressor
  • Both cooling bath temperature is same with ±1°C precision
  • Suitable to determine pour point and cloud point of petroleum oils
  • Fast and high cooling efficiency with easy usage
Pour and cloud point tester is used for precise and convenient flow testing of petroleum products, biodiesel fuels, additives and lubricating oils etc.

Low Temperature Tester

Solidifying Point Tester LLTT-A13

Solidifying Point Tester LLTT-A13

  • Temperature controlling accuracy
  • ± 0.5 ℃
  • Refrigeration system
  • New-type refrigeration compressor
  • Cold trough
  • Two holes in one trough, and same temperature
Multifunctional Low Temperature Tester LLTT-A16

Multifunctional Low Temperature Tester LLTT-A16

  • Refrigeration system
  • New-type refrigeration compressor
  • Controlling temperature of cold trough
  • Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
  • Ambient temperature
  • ≤ 30 ℃
Solidifying Point Constant Temperature Water Bath LLTT-A10

Solidifying Point Constant Temperature Water Bath LLTT-A10

  • Capacity
  • 20 L
  • Temperature range
  • Ambient +5°C to 100°C
  • Precision
  • ± 0.1℃
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • Ambient temperature
  • (-10)℃ ~ 35 ℃
  • Relative humidity
  • ≤ 85 %
  • Sample cup Inner diameter
  • 31.0 ~ 32.0 mm

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max
Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON

Acid and Alkali Tester

Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml

Aniline Test Equipment

Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V
Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W