UV absorption ozone meter LUOM-A10 is a portable unit used to measure ozone concentrations. It offers a wide detection range along with real time data recording. A built-in printer facilitates direct printing of current and pre-recorded data for end user convenience.

Ozone measurement range 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm
Flow rate 1 L/min
Accuracy 0.01 ppm
Measuring time 10 seconds
Boot time ≤ 10 min
UV source and life UV lamp ( 254 nm )<hr> 5000 hours
Gas pipe dimension Ø 4 mm
Operating temperature 0 °C ∼ 40 °C
Operating humidity 10 % ∼ 60 % RH
Print time interval 10 seconds
Print format 2001/01/01 11:01<hr> 000.001 ppm
Communication interface USB , WiFi (optional)
Power supply AC 220 ± 10 % 50 Hz ± 5 %
Dimensions 280 x 300 x 195 mm
Weight 5.5 kgs
  • Measuring mode : Semi-automatic
  • Wide detection range
  • LCD screen for digital display of detected ozone concentration
  • Internal data logger
  • Large data storage capacity ( 16000 samples )
  • PTFE inert material in gas flow pipeline reduces ozone loss
  • High precision and stable capability
  • Built-in battery
Used in ozone preparation workshop, detection of ozone concentration in ozone sterilizing cabinets, medical devices, and atmospheric environment; for determination of antioxidant capacity of analytical instruments; in industries such as chemical, petroleum, paper making, spinning, textile, pharmaceutical, water treatment, food and drug sterilization etc.

UV-Absorption Ozone Meter

Gas Detectors

Portable Nitrogen N2 Gas Detector LNGD-A10

Portable Nitrogen N2 Gas Detector LNGD-A10

  • Gas Detected
  • Nitrogen N2
  • Detection principle
  • Electrochemical principles
  • Measurement Range
  • 0 to 100 %.Vol
Portable SO2Gas Detector LPSG-A20

Portable SO2Gas Detector LPSG-A20

  • Gas detected
  • Sulfur dioxide SO2
  • Detection principle
  • Electrochemistry
  • Sampling method
  • Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Portable 10 in 1 Multi Gas Detector LMGD-A10

Portable 10 in 1 Multi Gas Detector LMGD-A10

  • Gas Detected
  • O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3
  • Detection principle
  • Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)
  • Measurement Range
  • O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM
Portable Single Gas Detector LPSG-A10

Portable Single Gas Detector LPSG-A10

  • Sampling method
  • Diffusion
  • Measurement principle
  • Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)
  • Detector gas
  • Flammable gases, oxygen gas, toxic and harmful gases

Digital Differential Pressure Meter

Digital Differential Pressure Meter LDPM-A20

Digital Differential Pressure Meter LDPM-A20

  • Measuring range
  • ± 500 Pa
  • Repeatability
  • ± 0.2 % FS
  • Resolution
  • 0.1 Pa
Digital Differential Pressure Meter LDPM-A10

Digital Differential Pressure Meter LDPM-A10

  • Measuring range
  • 0 ∼ 125 Pa
  • Accuracy
  • 0 ± 0.2 Pa (liner error) ± 1 %
  • Operating temperature range
  • 0 °C ∼ 50 °C

Handheld Ozone Tester

Handheld Ozone Tester LHOT-A10

Handheld Ozone Tester LHOT-A10

  • Measurement range
  • 0 ppm ∼ 5 ppm
  • Resolution
  • 0.001 ppm ( 0 ppm ∼ 5 ppm )
  • Temperature range
  • ˗ 40 °C ∼ 120 °C

Online Ozone Meter

Online Ozone Meter LOOM-A10

Online Ozone Meter LOOM-A10

  • Ozone measurement range
  • 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )
  • Flow rate
  • 1.5 L/min
  • Accuracy
  • 0.01 ppm or 3 % of reading