Portable Single Gas Detector LPSG-A10 is a compact, lightweight detector. Detects the concentration of flammable gases, oxygen gas, and different types of toxic and harmful gases. It features large capacity lithium battery with long standby time, adjustable calibration concentration, and manual cancellation mode of vibration alarms.

Sampling method Diffusion
Measurement principle Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)
Detector gas Flammable gases, oxygen gas, toxic and harmful gases
Response time <table cellspacing=0 border=1> <tr> <td style=min-width:50px>CO2 < 10 s </td> </tr> <tr> <td style=min-width:50px>O2, flammable gases < 20 s </td> </tr> <tr> <td style=min-width:50px>CO, H2S, SO2, NO, ClO2, NO2, H2 < 30 s </td> </tr> <tr> <td style=min-width:50px>HCN, NH3, PH3 < 100 s </td> </tr> </table>
Detection error ± 5 % F.S.
Explosion grade Exia II CT3
Operation mode Touch push keys
Display LCD display
Working temperature -20 to 55°C
Environment humidity 0 to 95 % RH (non-condensation)
Storage temperature 0 to 40°C
Battery 4.2 V lithium battery, 1700 mA/h
Power supply Rechargeable lithium battery, continuous working up to 24 hours
Dimension 125 × 66 × 42 mm
Weight 105 g
HS Code 9027100090
  • Single gas detection unit
  • Display real time detection values
  • Segment encoding LCD display
  • Setting for Upper and Lower alarm limit as per requirement
  • Adjustable backlight brightness to save power
  • Alarm beeps at different frequencies under different alarm conditions
  • Adjustable calibration concentration, facilitates user for calibration
  • Automatic battery detection (under voltage indication)
  • User can modify password to maintain privacy of test operations
Used in petroleum, chemical, fuel processing industry, metal manufacturing plants, drug production plants.

Gas Detectors

Handheld C2H4 Ethylene Gas Detector LEGD-A10

Handheld C2H4 Ethylene Gas Detector LEGD-A10

  • Sampling
  • With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
  • Gas
  • Ethylene C2H4
  • Measure Range
  • 0 to 1000 ppm
Portable 2 in 1 gas detector LPTG-A10

Portable 2 in 1 gas detector LPTG-A10

  • Sampling method
  • Diffusion
  • Sensor type
  • CO2: solid electrolyte sensor, O2:electrochemical sensor
  • Detection range
  • CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Portable SO2Gas Detector LPSG-A20

Portable SO2Gas Detector LPSG-A20

  • Gas detected
  • Sulfur dioxide SO2
  • Detection principle
  • Electrochemistry
  • Sampling method
  • Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Portable infrared gas detector LIGD-A10

Portable infrared gas detector LIGD-A10

  • Measurement principle
  • Non-dispersive infrared  (NDIR)
  • Gas Detected
  • SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
  • Detection Uncertainty

Digital Differential Pressure Meter

Digital Differential Pressure Meter LDPM-A10

Digital Differential Pressure Meter LDPM-A10

  • Measuring range
  • 0 ∼ 125 Pa
  • Accuracy
  • 0 ± 0.2 Pa (liner error) ± 1 %
  • Operating temperature range
  • 0 °C ∼ 50 °C
Digital Differential Pressure Meter LDPM-A20

Digital Differential Pressure Meter LDPM-A20

  • Measuring range
  • ± 500 Pa
  • Repeatability
  • ± 0.2 % FS
  • Resolution
  • 0.1 Pa

Handheld Ozone Tester

Handheld Ozone Tester LHOT-A10

Handheld Ozone Tester LHOT-A10

  • Measurement range
  • 0 ppm ∼ 5 ppm
  • Resolution
  • 0.001 ppm ( 0 ppm ∼ 5 ppm )
  • Temperature range
  • ˗ 40 °C ∼ 120 °C

Online Ozone Meter

Online Ozone Meter LOOM-A10

Online Ozone Meter LOOM-A10

  • Ozone measurement range
  • 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )
  • Flow rate
  • 1.5 L/min
  • Accuracy
  • 0.01 ppm or 3 % of reading

UV-Absorption Ozone Meter

UV Absorption Ozone Meter LUOM-A10

UV Absorption Ozone Meter LUOM-A10

  • Ozone measurement range
  • 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm
  • Flow rate
  • 1 L/min
  • Accuracy
  • 0.01 ppm