Table Top Spectrophotometer LTS-A16 works on dual optical path spectrum analysis technology with full wavelength range for color and transmittance measurement. It adopts reflectance D/8° and transmittance D/0° geometry to measure both opaque and transparent materials. Four types of UV modes are used for fluorescence material measurement. Equipped with touch screen rotatable display screen and android operating system. It is ideal used for color measurement in textile, chemical, petroleum, oil industries.

Wavelength Range 360 nm to 780 nm
Wavelength Pitch 10 nm
Sensor Silicon Photodiode Array
Grating Method Concave Grating
Sphere Diameter 152 mm
Half Band Width 5 nm
Reflectance Range 0 to 200 %
Resolution 0.0001
Light Source Pulse Xenon Lamp<br/> LED
UV Measurement Include UV, 400nm cut, 420nm cut, 460nm cut
Operating Temperature 5 ℃ to 40 ℃
Storage Temperature -20 ℃ to 45 ℃
Relative Humidity 80 % RH (at 35 ℃)
Measurement Time SCI/SCE < 2<br/> SCI+SCE < 4s
Measurement Aperture Reflectance: XLAV Φ30mm<br/> LAV 18mm,MAV Φ11mm<br/> SAV Φ6mm<br/> Transmittance:Φ25mm (Auto aperture size recognition)
Viewing Angles 2° and 10°
Transmittance Sample Size No limit on sample width and height<br/> Thickness ≤ 50mm
Repeatability XLAV Spectrum Reflectance/Transmittance: standard deviation within 0.1%<br/> XLAV Chromaticity value: Standard deviation within ΔE*ab 0.015 * When a white calibration plate is measured 30 x at 5-second intervals after white calibration
Inter-Instrument Agreement XLAV ΔE*ab 0.15 (BCRA Series II, Average measurement of 12 tiles, at 23℃)
Illuminants A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84
Display Reflectance and Transmittance graph/value, color value, color difference values, pass/fail, color simulation, color assessment, haze, liquid chromaticity values, color tendency
Color Spaces L*a*b, L*C*h, Hunter Lab, Yxy, XYZ
Color Difference ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔE*ab(hunter),555 shade sort
Other Indices WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Stensby),YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00),Metamerism index milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA/Pt-Co/Hazen, Gardner, Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength
Other Functions 1. Camera to view measurement area<br/> 2. Support horizontal, vertical and downward measurement method (need optional accessories to support for downward measurement)<br/> 3. Auto humidity and temperature compensation function
Illumination/ Viewing System Reflection: d/8(Diffused illumination, 8 degree viewing) Simultaneous measurement of SCI/SCE (ISO7724/1, CIE No.15, ASTM E1164, ASTM-D1003-07, DIN5033 Teil7,JIS Z8722 Condition C standard) Transmittance d/0(Diffused illumination, 0 degree viewing )
Interface USB<br/> USB-B<br/> RS-232
Screen Size 7 Inches Touch Screen
Storage Memory 8 GB U Disk for data storage and transfer
Power 12V/3A
Dimensions (L × W × H) 430 × 240 × 260 mm
Weight 10.8 kg
  • Dual optical paths spectrum analysis technology
  • Four type of UV test modes
  • Compatibility with SCI/SCE measurement system
  • Adopts D/8 geometry to meet color measurement
  • Android operating system with rotating 7 inch touch display screen
  • Open transmittance measurement are without specific sample size
  • Switchable reflectance apertures
  • Large storage memory
Widely used in the color and transmittance measurement in the industrial samples like plastic plate, powder material, petroleum and oil, textile and yarn, pellet materials, printing ink and packing material.

Table Top Spectrophotometer

Table top spectrophotometer LTS-A10

Table top spectrophotometer LTS-A10

  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table top spectrophotometer LTS-A11

Table top spectrophotometer LTS-A11

  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer LTS-A15

Table Top Spectrophotometer LTS-A15

  • Wavelength Range
  • 400 nm to 700 nm
  • Wavelength Interval
  • 10 nm
  • Sensor
  • High sensitivity silicon photodiode
Table top spectrophotometer LTS-A13

Table top spectrophotometer LTS-A13

  • Illumination system
  • d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double beam UV-Visible Spectrophotometer LUS-B14

Double beam UV-Visible Spectrophotometer LUS-B14

  • Wavelength range
  • 190 ~ 1100 nm
  • Spectral bandwidth
  • 1.8 nm
  • Wavelength accuracy
  • ± 0.3 nm
Double Beam UV/Vis Spectrophotometer LUS-B32

Double Beam UV/Vis Spectrophotometer LUS-B32

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 0.5/1/2/4/5 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV-Vis Spectrophotometer LUS-B11

Double Beam UV-Vis Spectrophotometer LUS-B11

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1.8 nm
  • Optical system
  • Double beam; 1200 lines/mm grating
Double beam UV-Visible Spectrophotometer LUS-B15

Double beam UV-Visible Spectrophotometer LUS-B15

  • Wavelength range
  • 190 ~ 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength accuracy
  • 0.5 nm

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-B10

Nano Spectrophotometer LNS-B10

  • Wavelength
  • 260 nm and 280 nm; Fixed
  • Spectral resolution
  • ≤ 8 nm
  • Path length
  • 0.5 mm
Nano Spectrophotometer LNS-C11

Nano Spectrophotometer LNS-C11

  • Cuvette
  • Yes
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm
Nano Spectrophotometer LNS-A21

Nano Spectrophotometer LNS-A21

  • Wavelength range
  • 200 - 850 nm
  • Path length
  • 1 mm, 2 mm, 5 mm, 10 mm
  • Wavelength accuracy
  • ± 1 nm
Nano Spectrophotometer LNS-C13

Nano Spectrophotometer LNS-C13

  • Cuvette
  • Yes
  • Temperature
  • 4 ºC - 42 ºC (Heating & Cooling)
  • PC
  • Inbuilt

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Vis Spectrophotometer LUS-A50

Single Beam UV/Vis Spectrophotometer LUS-A50

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Single Beam UV/Visible Spectrophotometer LUS-A10

Single Beam UV/Visible Spectrophotometer LUS-A10

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer LUS-A40

Single Beam UV/Visible Spectrophotometer LUS-A40

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer LUS-A22

Single Beam UV/Visible Spectrophotometer LUS-A22

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 0.5 nm, 1 nm, 2 nm, 4 nm adjustable
  • Wavelength Accuracy
  • ± 0.3 nm

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Vis Spectrophotometer LVS-C11

Vis Spectrophotometer LVS-C11

  • Wavelength Range
  • 320 ~ 1000 nm
  • Spectral Bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.5 nm
Vis Spectrophotometer LVS-B10

Vis Spectrophotometer LVS-B10

  • Wavelength Range
  • 325 ~ 1000 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Vis Spectrophotometer LVS-C10

Vis Spectrophotometer LVS-C10

  • Wavelength Range
  • 320 ~ 1100 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 0.5 nm
Vis Spectrophotometer LVS-A11

Vis Spectrophotometer LVS-A11

  • Wavelength Range
  • 335 ~ 1000 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 2 nm