Nano spectrophotometer is micro volume UV spectrophotometer which takes measurements at 230 nm, 260 nm, 280 nm. It utilizes CCD detector, Xenon flash lamp as light source which has high stability and long operating life. They are used to detect micro volume quantities of nucleic acids and other concentrated or dilute components is specially designed to analyze the concentration of pure of nucleic acid. The data can be printed with built in printer and can be transferred via SD- RAM card or USB. It requires only minimal amount of sample for accurate measurement.

Wavelength range 230 nm, 260 nm, 280 nm
Path length 1.0 mm, 0.2 mm
Minimum Sample size 0.3 - 2.0 µl
Absorbance range 0.2 - 75A (10 mm equivalent absorbance)
Absorbance precision 0.002 Abs
Absorbance accuracy 0.01
Light source Xenon flash lamp
Measurement time < 5 s
Detects nucleic acid up to 10 - 3750 ng/µL (dsDNA)
Detects protein up to 0.5 - 110 mg/mL (BSA)
Dimension 240 x 220 x 140 mm
Weight 2.35 kg
  • Wavelength measurement at 230 nm, 260 nm, 280 nm
  • 0.5 µl - 2.0 µl micro-volume sample for direct measurement onto pedestal
  • Rapid measure speed
  • Touch screen & panel operations with user friendly software
  • Long life Xenon flash lamp (10 flashes up to 10 years)
  • Highly concentrated samples can be used
  • Direct Concentration display
  • No cell or cuvettes are required
  • No necessary of PC
The nano spectrophotometer is used in laboratory, food industries, chemistry, microbiology, medicine research and development.

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-B10

Nano Spectrophotometer LNS-B10

  • Wavelength
  • 260 nm and 280 nm; Fixed
  • Spectral resolution
  • ≤ 8 nm
  • Path length
  • 0.5 mm
Nano Spectrophotometer LNS-B20

Nano Spectrophotometer LNS-B20

  • Wavelength Range
  • 200 to 800 nm
  • Sample Size
  • 0.5 to 2.0 µl
  • Path length
  • 0.05 mm 0.2 mm 1.0 mm
Nano Spectrophotometer LNS-A21

Nano Spectrophotometer LNS-A21

  • Wavelength range
  • 200 - 850 nm
  • Path length
  • 1 mm, 2 mm, 5 mm, 10 mm
  • Wavelength accuracy
  • ± 1 nm
Nano Spectrophotometer LNS-C11

Nano Spectrophotometer LNS-C11

  • Cuvette
  • Yes
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B31

Double Beam UV/Vis Spectrophotometer LUS-B31

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV-Vis Spectrophotometer LUS-B13

Double Beam UV-Vis Spectrophotometer LUS-B13

  • Wavelength Range
  • 190 to 1100 nm
  • Spectral Bandwidth
  • 1.0 nm
  • Optical System
  • Double beam
Double Beam UV/Vis Spectrophotometer LUS-B30

Double Beam UV/Vis Spectrophotometer LUS-B30

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV-Vis Spectrophotometer LUS-B12

Double Beam UV-Vis Spectrophotometer LUS-B12

  • Wavelength Range
  • 190 to 1100 nm
  • Spectral Bandwidth
  • 1.8 nm
  • Optical System
  • Split double beam, C-T monochromator,1200 L/mm holographic grating

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Vis Spectrophotometer LUS-A51

Single Beam UV/Vis Spectrophotometer LUS-A51

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Single Beam UV/Visible Spectrophotometer LUS-A20

Single Beam UV/Visible Spectrophotometer LUS-A20

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Single Beam UV/Visible Spectrophotometer LUS-A11

Single Beam UV/Visible Spectrophotometer LUS-A11

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1.8 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer LUS-A40

Single Beam UV/Visible Spectrophotometer LUS-A40

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
  • Wavelength Accuracy
  • ± 0.3 nm

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Visible Spectrophotometer LVS-A21

Visible Spectrophotometer LVS-A21

  • Photometry
  • Single Beam
  • Monochromatic Type
  • Czerny-Turner
  • Wavelength range
  • 325 to 1000nm
Vis Spectrophotometer LVS-C11

Vis Spectrophotometer LVS-C11

  • Wavelength Range
  • 320 ~ 1000 nm
  • Spectral Bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.5 nm
Vis Spectrophotometer LVS-C10

Vis Spectrophotometer LVS-C10

  • Wavelength Range
  • 320 ~ 1100 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 0.5 nm
Visible Spectrophotometer LVS-A20

Visible Spectrophotometer LVS-A20

  • Photometry
  • Single Beam
  • Monochromatic Type
  • Czerny-Turner
  • Wavelength range
  • 340 to 1000nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A11

Atomic Absorption Spectrophotometer LAAS-A11

  • Wavelength range
  • 190 - 900 nm
  • Spectral Bandwidth
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Wavelength accuracy
  • ≤ ± 0.5 nm
Atomic Absorption Spectrophotometer LAAS-A21

Atomic Absorption Spectrophotometer LAAS-A21

  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
  • Wavelength accuracy
  • ≤ 0.15 nm
Flame Atomic Absorption Spectrophotometer LAAS-A12

Flame Atomic Absorption Spectrophotometer LAAS-A12

  • Wavelength range
  • 190 nm ~ 900 nm
  • Spectral bandwidth
  • 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm
  • Wavelength accuracy
  • ± 0.25 nm
Atomic Absorption Spectrophotometer LAAS-A22

Atomic Absorption Spectrophotometer LAAS-A22

  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy
  • ≤ 0.15 nm