Single Beam UV/Vis Spectrophotometer is formulated with large LCD display screen and 4 cell holder capacity. It has full functionality from 190 – 1100 nm range of wavelength. It has wide range spectral bandwidth of 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm. This single beam spectrophotometer has highly stable optics with 1200 lines/mm grating. Spectrophotometer is complied using ISO/CE international standards. It is particularly designed to meet its versatility in research and industries.

Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Photometric Range 0 - 200 % T, (-0.3) to (-3.0)A, 0 - 9999 C
Photometric Accuracy ± 0.3 % T
Photometric Repeatability 0.2 % T
Detector Silicon Photodiode
Light Source Deuterium & Tungsten Halogen Lamp
Stray Light ≤ 0.05 % T at 220 nm, 360 nm
Stability 0.002 A / h at 500 nm
Data Output Port USB
Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
Noise ± 0.001 A
Display LCD Display resolution 320 × 240 Dots LCD
Optical System Single Beam (1200 lines / mm grating)
Baseline Flatness ± 0.001 A
Printer Port Parallel Port
Packing Size 860 x 660 x 465 mm
Packing Weight 35 kg
  • Single beam spectrophotometer
  • Wavelength range 190 nm to 1100 nm
  • Wide range of bandwidth 0.5 / 1.0 /2.0 / 4.0 / 5.0 nm with PC software
  • Optical system with 1200 lines / mm grating
  • 4 cell holder available along with USB port for data storage
  • 6 inches LCD display & integrated user interface
  • Extensive range of accessories available
Single Beam UV/Vis Spectrophotometer is ideal for quality control, general research, pharmaceuticals, biochemical and clinical laboratory applications.

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Visible Spectrophotometer LUS-A20

Single Beam UV/Visible Spectrophotometer LUS-A20

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Single Beam UV/Vis Spectrophotometer LUS-A52

Single Beam UV/Vis Spectrophotometer LUS-A52

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 0.5/1/2/4/5 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Single Beam UV/Visible Spectrophotometer LUS-A21

Single Beam UV/Visible Spectrophotometer LUS-A21

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 1.8 nm
Single Beam UV/Vis Spectrophotometer LUS-A51

Single Beam UV/Vis Spectrophotometer LUS-A51

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B16

Double Beam UV/Vis Spectrophotometer LUS-B16

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Double Beam UV-Vis Spectrophotometer LUS-B13

Double Beam UV-Vis Spectrophotometer LUS-B13

  • Wavelength Range
  • 190 to 1100 nm
  • Spectral Bandwidth
  • 1.0 nm
  • Optical System
  • Double beam
Double Beam UV-Vis Spectrophotometer LUS-B40

Double Beam UV-Vis Spectrophotometer LUS-B40

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 0.5/1/2/4 nm
  • Wavelength Accuracy
  • ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range
Double Beam UV-Vis Spectrophotometer LUS-B10

Double Beam UV-Vis Spectrophotometer LUS-B10

  • Wavelength Range
  • 190 to 1100 nm
  • Spectral Bandwidth
  • 1.8 nm
  • Optical System
  • Double beam

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-B20

Nano Spectrophotometer LNS-B20

  • Wavelength Range
  • 200 to 800 nm
  • Sample Size
  • 0.5 to 2.0 µl
  • Path length
  • 0.05 mm 0.2 mm 1.0 mm
Nano Spectrophotometer LNS-B10

Nano Spectrophotometer LNS-B10

  • Wavelength
  • 260 nm and 280 nm; Fixed
  • Spectral resolution
  • ≤ 8 nm
  • Path length
  • 0.5 mm
Nano Spectrophotometer LNS-C10

Nano Spectrophotometer LNS-C10

  • Cuvette
  • No
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm
Nano Spectrophotometer LNS-A20

Nano Spectrophotometer LNS-A20

  • Wavelength range
  • 190 to 850 nm
  • Wavelength accuracy
  • ± 1 nm
  • Wavelength Resolution
  • 2 nm (FWHM at Hg 546 nm)

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Visible Spectrophotometer LVS-A20

Visible Spectrophotometer LVS-A20

  • Photometry
  • Single Beam
  • Monochromatic Type
  • Czerny-Turner
  • Wavelength range
  • 340 to 1000nm
Vis Spectrophotometer LVS-A11

Vis Spectrophotometer LVS-A11

  • Wavelength Range
  • 335 ~ 1000 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 2 nm
Vis Spectrophotometer LVS-A10

Vis Spectrophotometer LVS-A10

  • Wavelength Range
  • 330 to 1000 nm
  • Spectral Bandwidth
  • 5 nm
  • Wavelength Accuracy
  • ± 2 nm
Vis Spectrophotometer LVS-B10

Vis Spectrophotometer LVS-B10

  • Wavelength Range
  • 325 ~ 1000 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Flame Atomic Absorption Spectrophotometer LAAS-A12

Flame Atomic Absorption Spectrophotometer LAAS-A12

  • Wavelength range
  • 190 nm ~ 900 nm
  • Spectral bandwidth
  • 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm
  • Wavelength accuracy
  • ± 0.25 nm
Atomic Absorption Spectrophotometer LAAS-A11

Atomic Absorption Spectrophotometer LAAS-A11

  • Wavelength range
  • 190 - 900 nm
  • Spectral Bandwidth
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Wavelength accuracy
  • ≤ ± 0.5 nm
Atomic Absorption Spectrophotometer LAAS-A20

Atomic Absorption Spectrophotometer LAAS-A20

  • Wavelength range
  • 180 - 900 nm
  • Spectral Bandwidth
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer LAAS-A22

Atomic Absorption Spectrophotometer LAAS-A22

  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy
  • ≤ 0.15 nm