Visible spectrophotometer LVS-C10 comes with large memory space which can store multiple sets of data & curves. With wavelength range of 320 ~ 1100 nm, standard curve for quantitative measurement can be established in simple method. It has with monolithic, microprocessor controlled LCD display of 128 × 64 bit. Quantitative measurement of standard curve is established through direct input of K & B factor. It is useful in scientific research and industries for detection of impurities and other elements.

Wavelength Range 320 ~ 1100 nm
Spectral Bandwidth 4 nm
Wavelength Accuracy ± 0.5 nm
Wavelength Repeatability ≤ 0.2 nm
Photometric Range (-0.3) ~ 3 A
Photometric Accuracy ± 0.3 % T
Photometric Repeatability 0.15 % τ
Detector Import Silicon Photodiode Detector
Light Source Import Tungsten Lamp
Stray Light ≤ 0.05 % τ
Stability 0.001 A / h 30 min at 500 nm
Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
Dimensions 480 × 350 × 220 mm
Weight 11 kg
Power 120 W
Display LCD Display resolution 128 × 64 Dots LCD
  • Wavelength range of 320 ~ 1100 nm
  • Large LCD display with 128 × 64 bit
  • Standard curve measurement function with ten standard sample
  • With general purpose parallel printer port and USB interface
  • Large sample cell(~ 5 mm to 100 mm)
  • Colour filter automatic switching
  • Auto wavelength setting
  • Can achieve more accurate and flexible measurement requirements
It is useful in scientific research and industries for quantitative and qualitative analysis, detection of impurities and functional groups determination.

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Visible Spectrophotometer LVS-A21

Visible Spectrophotometer LVS-A21

  • Photometry
  • Single Beam
  • Monochromatic Type
  • Czerny-Turner
  • Wavelength range
  • 325 to 1000nm
Visible Spectrophotometer LVS-A20

Visible Spectrophotometer LVS-A20

  • Photometry
  • Single Beam
  • Monochromatic Type
  • Czerny-Turner
  • Wavelength range
  • 340 to 1000nm
Visible Spectrophotometer LVS-A30

Visible Spectrophotometer LVS-A30

  • Wavelength range
  • 320 to 1100 nm
  • Spectral bandwidth
  • 2.0 nm
  • Wavelength Accuracy
  • ± 0.8 nm
Vis Spectrophotometer LVS-C11

Vis Spectrophotometer LVS-C11

  • Wavelength Range
  • 320 ~ 1000 nm
  • Spectral Bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.5 nm

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B16

Double Beam UV/Vis Spectrophotometer LUS-B16

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Double Beam UV-Vis Spectrophotometer LUS-B40

Double Beam UV-Vis Spectrophotometer LUS-B40

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 0.5/1/2/4 nm
  • Wavelength Accuracy
  • ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range
Double beam UV-Visible Spectrophotometer LUS-B14

Double beam UV-Visible Spectrophotometer LUS-B14

  • Wavelength range
  • 190 ~ 1100 nm
  • Spectral bandwidth
  • 1.8 nm
  • Wavelength accuracy
  • ± 0.3 nm
Double Beam UV-Vis Spectrophotometer LUS-B11

Double Beam UV-Vis Spectrophotometer LUS-B11

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1.8 nm
  • Optical system
  • Double beam; 1200 lines/mm grating

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-B10

Nano Spectrophotometer LNS-B10

  • Wavelength
  • 260 nm and 280 nm; Fixed
  • Spectral resolution
  • ≤ 8 nm
  • Path length
  • 0.5 mm
Nano Spectrophotometer LNS-C13

Nano Spectrophotometer LNS-C13

  • Cuvette
  • Yes
  • Temperature
  • 4 ºC - 42 ºC (Heating & Cooling)
  • PC
  • Inbuilt
Nano Spectrophotometer LNS-B11

Nano Spectrophotometer LNS-B11

  • Wavelength range
  • 230 nm, 260 nm, 280 nm
  • Path length
  • 1.0 mm, 0.2 mm
  • Minimum Sample size
  • 0.3 - 2.0 µl
Nano Spectrophotometer LNS-A20

Nano Spectrophotometer LNS-A20

  • Wavelength range
  • 190 to 850 nm
  • Wavelength accuracy
  • ± 1 nm
  • Wavelength Resolution
  • 2 nm (FWHM at Hg 546 nm)

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Visible Spectrophotometer LUS-A22

Single Beam UV/Visible Spectrophotometer LUS-A22

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 0.5 nm, 1 nm, 2 nm, 4 nm adjustable
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Vis Spectrophotometer LUS-A50

Single Beam UV/Vis Spectrophotometer LUS-A50

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Single Beam UV/Visible Spectrophotometer LUS-A10

Single Beam UV/Visible Spectrophotometer LUS-A10

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer LUS-A11

Single Beam UV/Visible Spectrophotometer LUS-A11

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1.8 nm
  • Wavelength Accuracy
  • ± 0.3 nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Flame Atomic Absorption Spectrophotometer LAAS-A12

Flame Atomic Absorption Spectrophotometer LAAS-A12

  • Wavelength range
  • 190 nm ~ 900 nm
  • Spectral bandwidth
  • 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm
  • Wavelength accuracy
  • ± 0.25 nm
Atomic Absorption Spectrophotometer LAAS-A20

Atomic Absorption Spectrophotometer LAAS-A20

  • Wavelength range
  • 180 - 900 nm
  • Spectral Bandwidth
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer LAAS-A21

Atomic Absorption Spectrophotometer LAAS-A21

  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer LAAS-A22

Atomic Absorption Spectrophotometer LAAS-A22

  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy
  • ≤ 0.15 nm