Ion Chromatograph LPIC-A10 is a light weight, portable design model with powerful data processing system. The quick ion chromatograph columns are used for rapid 5 min detection. Adopted with built –in multi-channel solvent selection valve helps in gradient elusion, it shortens peak time, and improves efficiency of the chromatograph conducted. Upgraded with dual detection system (dual column for various applications), supports the needs of different industries.

Chromatographic Pump <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Type</strong></td><td>High-pressure and low –pulse double plunger tandem advection pump</td></tr><tr><td><strong>Maximum Pressure</strong></td><td>35 MPa (PEEK)</td></tr><tr><td><strong>Flow Range</strong></td><td>0.001 to 9.999 mL/min</td></tr><tr><td><strong>Flow accuracy</strong></td><td>± 0.5 %</td></tr><tr><td><strong>Flow Repeatability</strong></td><td>RSD ≤ 0.1%</td></tr><tr><td><strong>Flow stability</strong></td><td>(0.2 to 0.5) mL/min, ≤ 3 %<br/> (0.5 to 1.0) mL/min, ≤ 2 %<br/> >1.0 mL/min, ≤ 2 %</td></tr></table>
Built-in Heat conduction type column heater <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Temperature range</strong></td><td>Room temperature +5°C to 60°C (41 to 140°F)</td></tr><tr><td><strong>Allowable deviation</strong></td><td>± 1°C</td></tr><tr><td><strong>Temperature stability</strong></td><td>≤ 0.5°C/h</td></tr></table>
Electromagnetic injection valve <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Maximum pressure</strong></td><td>35 MPa</td></tr><tr><td><strong>Control mode</strong></td><td>By stepper motor</td></tr><tr><td><strong>Power supply</strong></td><td>24 V (DC)</td></tr></table>
Digital and temperature control detection system <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Type</strong></td><td>Temperature control and bipolar conductivity detector</td></tr><tr><td><strong>Detection type</strong></td><td>Bipolar conductivity detection</td></tr><tr><td><strong>Cell volume</strong></td><td>≤ 0.8 µL</td></tr><tr><td><strong>Measurement range</strong></td><td>0 to 45000 µ S/cm (adjustable)</td></tr><tr><td><strong>Detection resolution</strong></td><td>≤ 0.0020 nS/cm</td></tr><tr><td><strong>Output voltage</strong></td><td>-6000 to 6000 mV (adjustable)</td></tr><tr><td><strong>Temperature range</strong></td><td>Room temperature +5°C to 60°C (41 to 140°F)</td></tr><tr><td><strong>Temperature accuracy</strong></td><td>± 0.01°C</td></tr><tr><td><strong>Maximum pressure</strong></td><td>10 MPa</td></tr><tr><td><strong>Baseline drift</strong></td><td>≤ 20 % FS/30 min</td></tr><tr><td><strong>Baseline noise</strong></td><td>≤0.5 % FS</td></tr><tr><td><strong>Instrument linearity</strong></td><td>≥ 0.999</td></tr><tr><td><strong>Quantitative Repeatability</strong></td><td>≤0.5 %</td></tr><tr><td><strong>Qualitative Repeatability</strong></td><td>≤2 %</td></tr><tr><td><strong>Minimum detectable concentration</strong></td><td>Cl-≤0.005 µg/mL<br/> Li+ ≤0.005 µg/mL</td></tr></table>
Flow system <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Plastic path flow</strong></td><td>Made of PEEK material</td></tr><tr><td><strong>Six way valve</strong></td><td>PEEK material pressure 5000 psi, independent automatic collecting and flow function</td></tr></table>
Panel computer <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Display screen</strong></td><td>12.3 inch</td></tr><tr><td><strong>Internal memory</strong></td><td>2G</td></tr><tr><td><strong>Weight</strong></td><td>786 g</td></tr></table>
External size (L × W × H) 440 × 226 × 420 mm
Net weight 8 kg
Gross weight 11 kg
  • Built-in column temperature control box for accurate experimental results
  • Capable with Flash column for rapid detection of anions and cations
  • Intelligent flow path clearing system for easy cleaning
  • Real time display
  • Wi-Fi connection for convenient data transfer
  • Continuous, non-stop 10 hours working system
  • Easy to operate
Used for on field selective analysis of organic and inorganic ions, also used in quality and research laboratories across pharmaceutical, water quality, chemical industries.

Portable Ion Chromatograph

Gas Chromatography

Gas Chromatography LGC-B11

Gas Chromatography LGC-B11

  • Oven
  • Maximum capacity22 LTemperature rangeRT + 5 ℃ to 400 ℃Temperature accuracy± 0.1 ℃Temperature program9-phase/ 10 platformProgram total time9999.9 minMaximum temperature heating rate0.1 to 60 ℃/ minMaximum cooling rate˂ 10 mins (250 to 50 ℃)
  • Sample injector
  • Temperature rangeRT+ 7 ℃ to 420 ℃Temperature controlAutomaticInjector typeColumn or splitMaximum sample inlet3 pcsCarrier gas flow typeConstant pressurePre column pressure range0 to 400 kPaPre column pressure accuracy0.1 kPaMobile phase flow rangeH2: 0 to 200 ml/min, N2: 0 to 150 ml/min
  • Detector
  • Temperature rangeRT + 7 ℃ to 420 ℃Maximum installationDual detectorFlame ignition modeAutomaticFlame Ionization Detector (FID)Logarithmic amplifier High voltage switch control Baseline signal display Ignition coil control Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane) Baseline noise: ≤ 5 × 10 - 14 A Baseline draft: ≤ 6 × 10 -13 A Dynamic range: 10 7 RSD: ≤ 3 %

Ion Chromatography

Ion chromatograph system LICS-A21

Ion chromatograph system LICS-A21

  • Ion Chromatographic Pump
  • TypeHigh pressure and low pulse double plunger tandem advection pumpMaximum pressure35 MPa (PEEK)Pressure display accuracy≤ 0.1 MPaFlow stability(0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 %Flow range0.001 to 9.999 ml/ minPressure pulse≤ 0.5%
  • Conductivity detector
  • TypeTemperature Control and Bipolar Conductivity DetectorDetection modeBipolar conductivity detectionCell volume≤ 0.8 µLDetection range0 to 45000 µS/ cmDetection resolution≤ 0.0020 nS/ cmOutput voltage- 6000 to +6000 mV (adjustable)Baseline noise≤ 0.05 % F.S.Baseline drift≤ 3 % FS/ 30 minOperating temperature rangeRoom temperature +5 to 60°C (41 to 140°F)Controlling temperature accuracy± 0.01°CMaximum pressure10 MPaLinear range≥ 103Instruments linearity≥ 0.999Quantitative repeatability≤ 1.0 %Qualitative repeatability≤ 1.0 %Minimum detectable concentrationCl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml
  • Flow system
  • Plastic flow pathMade of PEEK materialsSix way ValvePEEK material, 5000 psi pressure, independent automatic collection and flow function
Ion chromatograph system LICS-A20

Ion chromatograph system LICS-A20

  • Ion Chromatographic Pump
  • TypeHigh pressure and low pulse double plunger tandem advection pumpMaximum pressure35 MPa (PEEK)Pressure display accuracy≤ 0.1 MPaFlow stability(0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 %Flow range0.001 to 9.999 ml/ minPressure pulse≤ 0.5%
  • Conductivity detector
  • TypeTemperature Control and Bipolar Conductivity DetectorDetection modeBipolar conductivity detectionCell volume≤ 0.8 µLDetection range0 to 35000 µS/ cmDetection resolution≤ 0.0020 nS/ cmOutput voltage- 6000 to +6000 mV (adjustable)Baseline noise≤ 0.05 % F.S.Baseline drift≤ 3 % FS/ 30 minOperating temperature rangeRoom temperature +5 to 60°C (41 to 140°F)Controlling temperature accuracy± 0.01°CMaximum pressure10 MPaLinear range≥ 103Instruments linearity≥ 0.999Quantitative repeatability≤ 1.0 %Qualitative repeatability≤ 1.0 %Minimum detectable concentrationCl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml
  • Flow system
  • Plastic flow pathMade of PEEK materialsSix way ValvePEEK material, 5000 psi pressure, independent automatic collection and flow function
Ion chromatograph system LICS-A22

Ion chromatograph system LICS-A22

  • Ion Chromatographic pump
  • TypeHigh pressure and low pulse double plunger tandem advection pumpMaximum pressure35 MPa (PEEK)Display pressure accuracy≤ 0.1 MPaFlow stability(0.2 to 0.5) ml/ min ≤ 3 % , (0.5 to 1.0) ml/ min ≤ 2 %, > 1.0 ml/ min ≤ 2 %Flow range0.001 to 9.999 ml/ minPressure pulse≤ 0.5 %
  • Numerical control and electromagnetic injection
  • Maximum pressure35 MPaContact material of the rotorPEEKControl modeBy Stepper motorPower supplyDC 24 V
  • Column heater
  • Operating temperature rangeRoom temperature 20 to 60°C ( 68 to 140°F)Controlling temperature accuracy± 0.01°CAllowable deviation of column heater temperature± 2°CTemperature stability≤ 1°C/ h

GC-MS

Gas chromatography mass spectrometry GC-MS-879

Gas chromatography mass spectrometry GC-MS-879

  • Gas Chromatography Specifications
  • Model NoGC-87Flow rate1 ~ 1.5 ml / minMaximum flow rate10 ml / minInlet temperature450 °CPressure range0 ~ 100 psiHeating rateUpto 120 °C / minRoom temperature4 °C ~ 450 °CPressure control modeElectronic pressure control ( Supports CV and CC )Split modeSplit / split lessSplit ratio1000 : 1Temperature programming7 stages / 8 platformsAuto samplerOptional
  • Mass Spectrometry Specifications
  • Model NoMS-89Mass range1.5 ~ 1000 amuIon – source temperature100 °C ~ 350 °CGC-MS interface temperature450 °CScan rateUpto 10000 amu/sStability± 0.10 amu / 48 hrs.Filament emission current0 ~ 350 µAEI source ionization energy5 eV ~ 250 eVResolutionUnit resolutionDetectorHigh energy dynode electron multiplierSensitivityFull scan ( S / N is ≥ 30 : 1 )VacuumTurbo molecular pump ( 67 L/s )