Semi-automatic Microtome LSAM-A10 is a semi-automated unit with manual functionality for user convenience. Designed with built-in actuation system for precise tissue slicing, LCD display to show the slice and trimming thickness. Features a special sample retraction function preventing damage due to the abrasion between sample and the back of knife for smoother slicing, easy to dismantle waste bath dismantled, built-in safety alarm system alert the user for fault diagnosis.

Slice thickness range 0.5 µm to 100 µm (3 µm to 5 µm best slicing effect)
Trimming section range 1 µm to 600 µm
Horizontal specimen stroke 20 mm
Vertical specimen stroke 55 mm
Maximal slice section 50×45 mm
Specimen retraction 20 µm
Slip precision ± 5 %
Section thickness setting 0.5 to 5 µm, in 0.5 µm increment<br/> 5 to 20 µm, in 1 µm increment<br/> 20 to 60 µm, in 5 µm increment <br/> 60 to 100 µm, in 10 µm increment
Trimming thickness setting 1 to 10 µm, in 1 µm increment<br/> 10 to 20 µm, in 2 µm increment<br/> 20 to 50 µm, in 5 µm increment<br/> 50 to 100 µm, in 10 µm increment<br/> 100 to 600 µm, in 50 µm increment
Packing Dimension 680×560×480 mm
Gross Weight 50 kg
  • LCD screen shows the slice and trimming thickness
  • Adopted with advanced imported actuation system, for more precise tissue slicing
  • Sample retraction for prevention of sample damage
  • Can lock hand wheel in any position
  • Easy to disassembled waste bath
  • Safety alarm to alert the user for fault diagnosis
Semi-automatic Microtome widely used for sectioning (slicing, trimming) of biological specimens across Histopathology, Medicine filed for research and analysis.

Semi-automatic Microtome

Automatic Microtome

Automatic Microtome LAM-A10

Automatic Microtome LAM-A10

  • Section thickness range
  • 0.5 μm to 100 μm (3 to 5 μm best slicing effect)
  • Section thickness setting
  • 0.5 to 5 μm, in 0.5 μm increment 5 to 20 μm, in 1 μm increment 20 to 60 μm, in 5 μm increment 60 to 100 μm, in 10 μm increment
  • Trimming thickness range
  • 1 to 600 μm

Rotary Microtome

Rotary Microtome LRMI-A10

Rotary Microtome LRMI-A10

  • Slice thickness range
  • 0 to 60 µm
  • Section thickness setting
  • 0 to 2 µm in 0.5 µm increment 2 to 10 µm in 1 µm increment 10 to 20 µm in 2 µm increment 20 to 60 µm in 5 µm increment
  • Specimen stroke
  • Horizontal: 20 mm; Vertical: 50 mm

Vibrating Microtome

Vibrating Microtome LVMI-A10

Vibrating Microtome LVMI-A10

  • Specimen sectioning speed
  • 0 to 1.3 mm/s; Adjustable
  • Vibrating range
  • 0 to 1 mm
  • Section thickness range
  • 10 to 300 µm