Download Catalog for Gas Chromatography LGC-B11
www.labtron.website | info@labtron.website
Gas Chromatography LGC-B11 is a benchtop unit with advanced flow controller (AFC) technology. System has digital control mode and polar capillary columns to separate polar analytes. GC oven is capable of 9 temperature program ramps and hold steps, and features rapid cooling: 250 °C to 50 °C < 10 minutes. Accurate flow rate control via AFC has higher level repeatability of retention time and peak area, enabling specific level of analysis by means of dual FID detectors.
| Oven | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Maximum capacity</strong></td><td>22 L</td></tr><tr><td><strong>Temperature range</strong></td><td>RT + 5 ℃ to 400 ℃</td></tr><tr><td><strong>Temperature accuracy</strong></td><td>± 0.1 ℃</td></tr><tr><td><strong>Temperature program</strong></td><td>9-phase/ 10 platform</td></tr><tr><td><strong>Program total time</strong></td><td>9999.9 min</td></tr><tr><td><strong>Maximum temperature heating rate</strong></td><td>0.1 to 60 ℃/ min</td></tr><tr><td><strong>Maximum cooling rate</strong></td><td>˂ 10 mins (250 to 50 ℃)</td></tr></table> |
| Sample injector | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Temperature range</strong></td><td>RT+ 7 ℃ to 420 ℃</td></tr><tr><td><strong>Temperature control</strong></td><td>Automatic</td></tr><tr><td><strong>Injector type</strong></td><td>Column or split</td></tr><tr><td><strong>Maximum sample inlet</strong></td><td>3 pcs</td></tr><tr><td><strong>Carrier gas flow type</strong></td><td>Constant pressure</td></tr><tr><td><strong>Pre column pressure range</strong></td><td>0 to 400 kPa</td></tr><tr><td><strong>Pre column pressure accuracy</strong></td><td>0.1 kPa</td></tr><tr><td><strong>Mobile phase flow range</strong></td><td>H2: 0 to 200 ml/min, N2: 0 to 150 ml/min</td></tr></table> |
| Detector | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Temperature range</strong></td><td>RT + 7 ℃ to 420 ℃</td></tr><tr><td><strong>Maximum installation</strong></td><td>Dual detector</td></tr><tr><td><strong>Flame ignition mode</strong></td><td>Automatic</td></tr><tr><td><strong>Flame Ionization Detector (FID)</strong></td><td>Logarithmic amplifier <br/> High voltage switch control <br/> Baseline signal display <br/> Ignition coil control <br/> Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane) <br/> Baseline noise: ≤ 5 × 10 <sup> - 14 </sup> A <br/> Baseline draft: ≤ 6 × 10 <sup> -13 </sup> A <br/> Dynamic range: 10 <sup> 7 </sup> <br/> RSD: ≤ 3 %</td></tr></table> |
| Power supply | AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W |
| Packing dimension | 1020 × 660 × 740 mm |
| Gross Weight | 82 kg |
| Net weight | 70 kg |