Fluorescence Spectrophotometer LFS-A11

Fluorescence Spectrophotometer LFS-A11


Fluorescence Spectrophotometer LFS-A11 is a high performance equipment with a 150 W Xenon Lamp for providing sufficient light intensity signal to detect sensitivity. It is built for maintaining best possible accuracy. It contains characteristics like Ultra scanning speed, ultra high resolution, and ultra-high wavelength accuracy to meet most of the measurements. Quantum yield is also available for this fluorescence spectrophotometer.





Excitation Source150 W Xenon Lamp
Excitation Wavelength200 nm to 900 nm
Excitation Slit1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Emission Slit1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Wavelength Accuracy± 0.4 nm
Wavelength Repeatability≤ 0.2 nm
Signal-to-Noise RatioS/N ≥ 350 (P-P), S/N ≥ 1000 (RMS)
Limit≤ 5 × 10 -11 g /ml(Quinine Sulfate Solution)
Linearityγ ≥ 0.995
Peak Repeatability≤ 1.5 %
Wavelength Scan SpeedMulti-speed Level, Maximum at 60000 nm / min
Minimum sample size0.5 mL (Using a standard 10 mm square sample cell)
Octave filterBuild in Octave filter
Photometric Quantity Range-9999 to 9999
Response TimeAuto adjust (0.02 s, 0.1 s, 0.5 s, 1 s, 2 s, 4 s, 8 s )
Data TransportationUSB 2.0
Power200 W
Power SupplyAC 220 V / 50 Hz, 110 V / 60 Hz
Dimension610×460×365 mm
Net Weight21 kg
Gross Weight26 kg
  • Horizontal slit optical design with finite luminous detection efficiency and high SNR
  • Water Raman peak SNR better than 350: 1 (P-P) or 1000: 1 (RMS)
  • Standard 10 mm square sample cell utilizes minimum sample volume of 0.5 mL
  • Wavelength scanning speed is flexible and can reach up till 60000 nm / min
  • Adjustable bandwidth feature
  • Accessories are available for Fluorescence Quantum Yield
  • Software is versatile enough to offer functions like fluorescence 3D scanning, equal wavelength difference synchronous scanning, and equal wave number difference (constant energy difference) synchronous scanning
  • Synchronous scanning function require pro version software
  • Multiple accessories provided
  • Best quality assurance given by using 150 W Xenon Lamp, to provide sufficient light intensity signal to detect sensitivity
  • Unstable samples is analysed via built-in optical gate and built-in frequency filter
They can be widely applicable in material research, drug analysis, biochemical, scientific research clinical testing, water quality control, food safety testing and other areas covering quantity and quality analysis.
Accessory No. Accessory Name
1 Multi- function fluorescent sample rack holder
2 Base of other sample racks.
3 Membrane sample rack
4 Powder sample rack
5 Sample cell jacket
6 200 µL micro centrifuge tube accessory
7 Up conversion fluorescent accessory
8 Fluorescence Quantum Yield accessory

Related Products