Air Jacketed CO<sub>2</sub> Incubator LAJI-C20

Air Jacketed CO2 Incubator LAJI-C20


Air Jacketed CO 2 Incubator LAJI-C20 is a shaking CO2 incubator with air jacketed configurations suitable for heat/UV sterilization and temperature range of 4˚ to 65˚C with shaking frequency of 40 to 300 rpm. Designed with CO2 concentration sensor, advanced alarm system, temperature control and monitoring system, it provides uniform and stable conditions. Incorporated 90˚ C high temperature sterilization method, touch screen with PID controller, and enhanced safety features provides the benefits of contamination control and uncompromising temperature uniformity for even the most demanding incubations.





CO2 range0-20%
CO2 recovery time(Return to 5% after opening the door for 30 seconds) ≤3 mins
CO2 control accuracy±0.1%
CO2 stability of 5%CO2±0.1%
CO2 uniformity±0.1%
CO2 sensorIR CO2 sensor
Shaking frequency40-300 rpm
Shaking Precision±1 rpm
Amplitude20 mm
Drive wayThree eccentric shaft balance drive type
Humidity control50 to 90%
37C humidity control accuracyThe chamber can reach 85%-95% when 37˚ C , and the humidity can be controlled in real time
Humidity resolution0.001
Humidity deviation±2%
Related humidityNature vaporate > 95%
Allowable shaking load10 kg
Temperature control range4-65° C
Temperature control accuracy±0.1° C
Temperature uniformity±0.5° C
Temperature sensorPT 100
Environment temperature detectorIndependent
Over temperature protection systemIndependent
Temperature recover time(Return to 37˚ C after opening the door for 30 sec) ≤8 mins
Heating method6 side heating
Disinfection method90˚ C high temp
Timing range0 to 99 hour 59 min
Platform size (L×B)350×350 mm
Shelf1
DisplayDigital Color display with touch panel
Sterilization system90 degree high temp. high humidity sterilization system (RHP); UV sterilization (option)
ControllerPID
InterfaceRS485
Door Open/close messageYes
Alarm systemHigh and low temperature and over temperature; Chamber sensor failure; Independent temperature limiter; Door open; High/low CO2 condensation; Power off alarm; Door temperature sensor failure; Disinfection and sterilization status reminder; Over temp sensor failure and Abnormal function
Interior dimension (W×D×H)505×600×420 mm
Exterior dimension (W×D×H)693×875×753 mm
Gross Weight91 kg
Power1500 W
Voltage220V 50Hz
Flask Configuration50 ml×36, 100 ml×23, 250 ml×13, 500 ml×8, 1 L×5, 2 L×3, 4 L×1, 5 L×1
  • Touch screen interface with Screen lock while functioning
  • Infrared CO2 concentration sensor with PT100 temperature sensor
  • Outer door ring with heating function
  • Independent environment temperature detector
  • UV lamp at the back top of chamber
  • 90 degree high temperature and high humidity sterilization system with One touch simple sterilization function
  • Short sterilization cycle (18 hours) with 72 hours machine performance
  • Heating elements: Located on all 6 sides of the chamber
  • Alarm system: High and low temperature and over temperature; Chamber sensor failure; Independent temperature limiter; Door open; High/low CO2 condensation; Power off alarm; Door temperature sensor failure; Disinfection and sterilization status reminder; Over temp sensor failure and Abnormal function
  • Data logging capabilities with PID controller
  • Designed to minimize contamination
Air Jacketed CO2 Incubator are used for tissue engineering, cell culture, in vitro fertilization, diagnostics, neuroscience, cancer research and for developing biosensors across medical research and the pharmaceutical industry.